Exploring spatiotemporal information in a Cherenkov and scintillation photon counting BGO TOF-PET semi-monolithic detector concept
Physics in Medicine & Biology · 14.01.2026 · 71 (1) · 015032
DOI: 10.1088/1361-6560/ae2db7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physics in Medicine & Biology, online erschienen am 08.01.2026. Verfasst von Seungeun Lee und 3 weiteren Autor:innen. Beteiligte Einrichtung: Applied Nuclear Physics Program, Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA, United States of America. Hauptthemen laut MEDLINE: Photons, Positron-Emission Tomography, Germanium, Scintillation Counting. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, National Institute of Biomedical Imaging and Bioengineering.
Abstract (Originalsprache)
Objective . Cherenkov signatures from a bismuth germanate (BGO) crystal open the possibility of establishing BGO as a promising material for time-of-flight positron emission tomography (TOF-PET) detectors, particularly if the first Cherenkov photons can be uniquely timestamped. To maximize the utility of Cherenkov signatures, we employed an optical photon counting detector concept based on a thick, semi-monolithic BGO crystal coupled to a silicon photomultiplier (SiPM) array that provides digital photon timestamps from each SiPM channel. We characterized a prototype detector to demonstrate this concept and explored the use of rich spatiotemporal information of photon transport kinetics. Approach . The detector was built using a 42.68 × 2 × 20 mm 3 BGO crystal and a 16 × 1 array of 2 × 2 mm 3 SiPMs with a 2.68 mm pitch. A 16-channel low-noise high-frequency signal processing chain with fast comparators generated digital photon signals, which were recorded using waveform digitizers. Three-dimensional (3D) position calibration and first photon delay distribution (FPDD) construction provided the basis for data-driven methods to improve time resolution and estimate the probability of Cherenkov detection for each event. Main results . With a sufficient number of SiPM channels and 1.8 ns signal shaping, approximately 77% of events were uniquely timestamped with the first photon. FPDD clearly captured photon arrival properties, parameterized with the Cherenkov and scintillation contributions. A coincidence time resolution with a reference detector of 172 ps full width at half maximum was achieved by FPDD-based correction of 3D position dependence. Parameters investigated for Cherenkov detection probability estimation showed consistent correlation with time resolution. Significance . The results demonstrated the feasibility of a photon counting BGO detector for TOF-PET with both promising timing and positioning performance. The abundance of photon information provides a strong basis for further performance gains through data-driven Cherenkov identification and advanced event-by-event corrections.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Applied Nuclear Physics Program, Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA, United States of America.
ORCID-Profile: Seungeun Lee, Ryan Heller, Joshua W Cates
Förderung
- NIBIB NIH HHS
- National Institute of Biomedical Imaging and Bioengineering
Zitieren
APA
Lee, S., Heller, R., Choong, W. S., & Cates, J. W. (2026). Exploring spatiotemporal information in a Cherenkov and scintillation photon counting BGO TOF-PET semi-monolithic detector concept. Physics in Medicine & Biology, 71(1), 015032. https://doi.org/10.1088/1361-6560/ae2db7
Vancouver
Lee S, Heller R, Choong WS, Cates JW. Exploring spatiotemporal information in a Cherenkov and scintillation photon counting BGO TOF-PET semi-monolithic detector concept. Physics in Medicine & Biology. 2026;71(1):015032. doi:10.1088/1361-6560/ae2db7
BibTeX
@article{Lee2026,
author = {Lee, Seungeun and Heller, Ryan and Choong, Woon-Seng and Cates, Joshua W},
title = {Exploring spatiotemporal information in a Cherenkov and scintillation photon counting BGO TOF-PET semi-monolithic detector concept},
journal = {Physics in Medicine & Biology},
year = {2026},
volume = {71},
number = {1},
pages = {015032},
doi = {10.1088/1361-6560/ae2db7}
}
EUVIMED