Enhanced light extraction in flex-mold nanopatterned scintillators for TOF-PET
Physics in Medicine & Biology · 2026
DOI: 10.1088/1361-6560/ae97d1 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physics in Medicine & Biology, 2026. Verfasst von Suyeon Hyeon und 3 weiteren Autor:innen. Beteiligte Einrichtung: Electrical Engineering and Computer Science, Daegu Gyeongbuk Institute of Science and Technology, Daegu, Republic of Korea. Hauptthemen laut MEDLINE: Scintillation Counting, Positron-Emission Tomography, Light, Nanostructures. Die Arbeit nennt 50 Literaturangaben. Gefördert von: National Research Foundation of Korea.
Abstract (Originalsprache)
Objective. Optical photon losses at the scintillator–photosensor interface limit both energy and coincidence time resolution (CTR) in time-of-flight positron emission tomography (TOF-PET) detectors. To address this challenge, we applied diffractive nanopatterns on the surface of scintillation crystals to enhance light extraction. Approach. We utilized flex-mold-based soft lithography to imprint 300 nm hole and line patterns over cm-scale scintillator surfaces with less than 4% relative dimensional variation. Three scintillators (LYSO, BGO, GAGG) were tested under four optical coupling configurations: bare crystal with air (reference), bare with optical grease, nanopatterned crystal with air, and nanopatterned with grease. Main results. A 3 × 3 × 20 mm 3 BGO with an H _hole-plaid nanopattern combined with optical grease achieved a maximum light extraction gain of 2.22-fold compared to the bare crystal with air coupling. Its energy resolution improved from 18% to 11%. The same fabrication process was applied to 3 × 3 × 20 mm 3 LYSO and 5 × 5 × 5 mm 3 GAGG, yielding light extraction gains of 1.58- and 1.72-fold. We also performed CTR measurements on nanopatterned LYSO 3 × 3 × 20 mm 3 crystals, where the average CTR dropped from 250.6 ps (bare crystal with air coupling) to 142.6 ps ( P _line with optical grease) at a fixed leading-edge discriminator threshold. Further threshold optimization for P _line with optical grease yielded a best result of 132.0 ps. The nanopatterns retained most of their gain after mechanical loading and 20 cycles of repeated cleaning. Significance. These findings demonstrate that flex-mold-based soft nanoimprint lithography provides a practical, high-fidelity approach for surface engineering of TOF-PET systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Electrical Engineering and Computer Science, Daegu Gyeongbuk Institute of Science and Technology, Daegu, Republic of Korea.
- Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea.
ORCID-Profile: Suyeon Hyeon, Guen Bae Ko, Min Sun Lee
Förderung
- National Research Foundation of Korea
Zitieren
APA
Hyeon, S., Choi, S., Ko, G. B., & Lee, M. S. (2026). Enhanced light extraction in flex-mold nanopatterned scintillators for TOF-PET. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/ae97d1
Vancouver
Hyeon S, Choi S, Ko GB, Lee MS. Enhanced light extraction in flex-mold nanopatterned scintillators for TOF-PET. Physics in Medicine & Biology. 2026. doi:10.1088/1361-6560/ae97d1
BibTeX
@article{Hyeon2026,
author = {Hyeon, Suyeon and Choi, Suhan and Ko, Guen Bae and Lee, Min Sun},
title = {Enhanced light extraction in flex-mold nanopatterned scintillators for TOF-PET},
journal = {Physics in Medicine & Biology},
year = {2026},
doi = {10.1088/1361-6560/ae97d1}
}