Development of small, cost‐efficient scintillating fiber detectors for automated synthesis of positron emission tomography radiopharmaceuticals

Hailey Sae Hyun Ahn, Liam Carroll, Robert Hopewell, I-Huang Tsai, Dean Jolly, Gassan Massarweh, Shirin A Enger

Medical Physics · 2024

DOI: 10.1002/mp.17369 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, 2024. Verfasst von Hailey Sae Hyun Ahn und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oncology, Medical Physics Unit, McGill University, Montreal, Quebec, Canada. Hauptthemen laut MEDLINE: Positron-Emission Tomography, Radiopharmaceuticals, Monte Carlo Method. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Canada Research Chairs Program, CHRP (NSERC+CIHR).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Radiolabeling is critical in complex chemical reactions involving positron emission tomography (PET) radiotracer production. The process is now automated within a synthesis module to enhance efficiency and reduce radiation exposure. The key to this automation is the use of radiation detectors to monitor radioactivity transfer and ensure the progression of reactions. However, the high cost of these detectors has motivated the need for a more affordable alternative.

Purpose

This study aimed to develop a compact and cost‐efficient detector using scintillating fibers and silicon photomultipliers (SiPMs) to track radioactivity throughout PET radiotracer production.

Methods

Monte Carlo simulations were performed with the Geant4‐based M‐TAG software for four detector geometries (single fiber, single fiber with bolus, 16‐fiber bundle, and spiral) to optimize the detector construction for better detection efficiency. The simulations scored the energy deposited into the scintillating fibers per simulated particle, which was used to estimate the expected voltage pulse height from the SiPM considering the total light collection efficiency. Based on the simulation results, two detector configurations (16‐fiber bundle and spiral fiber) were constructed using plastic scintillating fibers, optical fibers, a 6 mm 6 mm SiPM, and commonly available electronic components. The detectors were calibrated using a Fluorine‐18 () source with typical activity levels used in radiotracer production. Detector performances were subsequently evaluated through linearity tests and measurement uncertainty assessments. Errors up to were considered acceptable for troubleshooting purposes.

Results

The calibration curves showed a linear response with changing activity for both detectors. The calibrated detectors offered real‐time activity measurements ranging from 0.10 to 49.41 GBq, with a 3‐s refresh rate. In the activity range above 0.145 GBq, the uncertainties were less than for both the 16‐fiber and spiral configurations. The spiral detector recorded a signal with a half‐life of min, closely aligning with the reference half‐life of .

Conclusions

Cost‐efficient plastic scintillation fiber detectors were developed to facilitate the troubleshooting of automated synthesis of PET radiotracers.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Positron-Emission TomographyRadiopharmaceuticalsMonte Carlo MethodScintillation CountingAutomationCost-Benefit AnalysisEquipment DesignOptical Fibers

Stichwörter der Autor:innen

PET radiopharmaceutical productionplastic scintillating fiberscintillation detector

Substanzen

Radiopharmaceuticals

Autor:innen und Institutionen

  • Department of Oncology, Medical Physics Unit, McGill University, Montreal, Quebec, Canada.
  • Montreal Neurological Institute, McGill University, Montreal, Quebec, Canada.
  • Lady Davis Institute for Medical Research, Jewish General Hospital, Montreal, Quebec, Canada.

Förderung

  • Canada Research Chairs Program
  • CHRP (NSERC+CIHR)

Zitieren

APA

Ahn, H. S. H., Carroll, L., Hopewell, R., Tsai, I. H., Jolly, D., Massarweh, G., & Enger, S. A. (2024). Development of small, cost‐efficient scintillating fiber detectors for automated synthesis of positron emission tomography radiopharmaceuticals. Medical Physics. https://doi.org/10.1002/mp.17369

Vancouver

Ahn HSH, Carroll L, Hopewell R, Tsai IH, Jolly D, Massarweh G, et al. Development of small, cost‐efficient scintillating fiber detectors for automated synthesis of positron emission tomography radiopharmaceuticals. Medical Physics. 2024. doi:10.1002/mp.17369

BibTeX
@article{Ahn2024,
  author = {Ahn, Hailey Sae Hyun and Carroll, Liam and Hopewell, Robert and Tsai, I-Huang and Jolly, Dean and Massarweh, Gassan and Enger, Shirin A},
  title = {Development of small, cost‐efficient scintillating fiber detectors for automated synthesis of positron emission tomography radiopharmaceuticals},
  journal = {Medical Physics},
  year = {2024},
  doi = {10.1002/mp.17369}
}
Kostenlos starten →