EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Comparison of physical approaches to inter-crystal scattering in a staggered-layer scintillation PET detector: a simulation study

Qi Liu iD, Jürgen J Scheins iD, Elisabeth Pfaehler iD, Keith George Ciantar iD, Debora Niekämper iD, Cláudia Régio Brambilla iD, Qingxian Zhang, N Jon Shah iD, Christoph Lerche iD

Physics in Medicine & Biology · 28.05.2026 · 71 (10) · 105017

DOI: 10.1088/1361-6560/ae674b ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Physics in Medicine & Biology, online erschienen am 26.05.2026. Verfasst von Qi Liu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Neuroscience and Medicine 4 (INM-4), Forschungszentrum Jülich GmbH, Jülich, Germany. Hauptthemen laut MEDLINE: Scintillation Counting, Scattering, Radiation, Positron-Emission Tomography, Monte Carlo Method. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Helmholtz -OCPC Postdoctoral Fellowship Programme, Deutsche Forschungsgemeinschaft, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective. Inter-crystal scattering (ICS) degrades spatial resolution and contrast by causing spurious lines of response in small-pitch, staggered three-layer pixelated LSO scintillation detectors used in a high-resolution BrainPET-7T insert. This work aimed to investigate the distribution of ICS events in our BrainPET-7T detector and understand its underlying mechanisms. Approach. Six physical approaches for computing probabilities to identify the first interaction positions of ICS events were studied using Geant4 simulations, focusing specifically on events with two interactions, which represent the most frequent ICS occurrence. Performance was evaluated using ideal interaction positions and energies directly from simulations, ground truth crystal-center positions with ideal energies, as well as crystal-center positions and energies determined by a maximum likelihood positioning (MLP) algorithm. Main results. A method based on Klein–Nishina probabilities computed using geometric information (KN-G), together with MLP-derived crystal-center positions and energies, achieved superior accuracy, particularly when the distance between successive interactions in Compton events was shorter than 6 mm and when incident angles were below 15 ∘ . This advantage is partly attributable to crystal-center discretization, which masks a substantial portion of backscattering events. It reached a peak accuracy of 92.2% at a distance of 19 mm. Significance. These findings demonstrate the feasibility of combining the KN-G method with the MLP algorithm to mitigate the ICS effects, with the potential to improve the image quality of the BrainPET-7T insert.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Scintillation CountingScattering, RadiationPositron-Emission TomographyMonte Carlo MethodCrystallization

Stichwörter der Autor:innen

Monte Carlo simulationsinter-crystal scatteringmaximum likelihood positioningpositron emission tomographyscintillation detector

Autor:innen und Institutionen

  • Institute of Neuroscience and Medicine 4 (INM-4), Forschungszentrum Jülich GmbH, Jülich, Germany.
  • College of Nuclear Technology and Automation Engineering, Chengdu University of Technology, Chengdu, People's Republic of China.
  • Department of Physics, RWTH Aachen University, Aachen, Germany.
  • Uniklinik RWTH Aachen, Physics of Molecular Imaging, Experimental Molecular Imaging, Aachen, Germany.
  • Institute of Neuroscience and Medicine 11 (INM-11), Forschungszentrum Jülich GmbH, Jülich, Germany.
  • JARA-BRAIN-Translational Medicine, Department of Neurology, RWTH Aachen University, Aachen, Germany.

ORCID-Profile: Qi Liu, Jürgen J Scheins, Elisabeth Pfaehler, Keith George Ciantar, Debora Niekämper, Cláudia Régio Brambilla, N Jon Shah, Christoph Lerche

Förderung

  • Helmholtz -OCPC Postdoctoral Fellowship Programme
  • Deutsche Forschungsgemeinschaft
  • National Natural Science Foundation of China
  • European Union

Zitieren

APA

Liu, Q., Scheins, J. J., Pfaehler, E., George Ciantar, K., Niekämper, D., Régio Brambilla, C., Zhang, Q., Jon Shah, N., & Lerche, C. (2026). Comparison of physical approaches to inter-crystal scattering in a staggered-layer scintillation PET detector: a simulation study. Physics in Medicine & Biology, 71(10), 105017. https://doi.org/10.1088/1361-6560/ae674b

Vancouver

Liu Q, Scheins JJ, Pfaehler E, George Ciantar K, Niekämper D, Régio Brambilla C, et al. Comparison of physical approaches to inter-crystal scattering in a staggered-layer scintillation PET detector: a simulation study. Physics in Medicine & Biology. 2026;71(10):105017. doi:10.1088/1361-6560/ae674b

BibTeX
@article{Liu2026,
  author = {Liu, Qi and Scheins, Jürgen J and Pfaehler, Elisabeth and George Ciantar, Keith and Niekämper, Debora and Régio Brambilla, Cláudia and Zhang, Qingxian and Jon Shah, N and Lerche, Christoph},
  title = {Comparison of physical approaches to inter-crystal scattering in a staggered-layer scintillation PET detector: a simulation study},
  journal = {Physics in Medicine & Biology},
  year = {2026},
  volume = {71},
  number = {10},
  pages = {105017},
  doi = {10.1088/1361-6560/ae674b}
}
Kostenlos starten →