Two Is Better than One: Aveir DR Leadless Pacemaker System with Dual-Chamber Pacing
Journal of Cardiothoracic and Vascular Anesthesia · 2025-01 · 39 (1) · 286-291
DOI: 10.1053/j.jvca.2024.10.020 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Journal of Cardiothoracic and Vascular Anesthesia, 2025-01. Verfasst von Jonathan E Tang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Ohio State University Wexner Medical Center, Columbus, OH. Electronic address: jonathan.tang@osumc.edu. Hauptthemen laut MEDLINE: Pacemaker, Artificial, Cardiac Pacing, Artificial. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 19 Literaturangaben.
Abstract (Originalsprache)
The Aveir DR dual-chamber Leadless Pacemaker system (Abbott Laboratories) was recently approved by the US Food and Drug Administration and is heralded to be the next generation of leadless pacemakers. Earlier generations of leadless pacemakers could only provide single-chamber right ventricular pacing, limiting their application to a small subset of patients in whom pacemaker therapy is indicated. With the expansion of pacing therapy, the Aveir DR system expands availability of leadless pacing to more patients. Although there have been prior documented experiences with the earlier generation of leadless pacemakers, the addition of a second leadless pacemaker to provide dual-chamber pacing adds new complexities. It is essential to understand what makes the Aveir DR system unique if an anesthesiologist were to come across one perioperatively.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anesthesiology, Ohio State University Wexner Medical Center, Columbus, OH. Electronic address: jonathan.tang@osumc.edu.
- Department of Anesthesiology, Ohio State University Wexner Medical Center, Columbus, OH.
- Department of Anesthesia, Pain Medicine, and Critical Care Medicine, Massachusetts General Hospital, Boston, MA.
- Division of Cardiovascular Medicine, Department of Internal Medicine, Ohio State University Wexner Medical Center, Columbus, OH.
Zitieren
APA
Tang, J. E., Guirguis, F., Holloway, J. O., Wernke, C., Reeves, J., Kumar, N. A., Savona, S. J., Essandoh, M. K., & Iyer, M. H. (2025). Two Is Better than One: Aveir DR Leadless Pacemaker System with Dual-Chamber Pacing. Journal of Cardiothoracic and Vascular Anesthesia, 39(1), 286-291. https://doi.org/10.1053/j.jvca.2024.10.020
Vancouver
Tang JE, Guirguis F, Holloway JO, Wernke C, Reeves J, Kumar NA, et al. Two Is Better than One: Aveir DR Leadless Pacemaker System with Dual-Chamber Pacing. Journal of Cardiothoracic and Vascular Anesthesia. 2025;39(1):286-291. doi:10.1053/j.jvca.2024.10.020
BibTeX
@article{Tang2025,
author = {Tang, Jonathan E and Guirguis, Fady and Holloway, Jordan O and Wernke, Cassidy and Reeves, Jeremy and Kumar, Nicolas A and Savona, Salvatore J and Essandoh, Michael K and Iyer, Manoj H},
title = {Two Is Better than One: Aveir DR Leadless Pacemaker System with Dual-Chamber Pacing},
journal = {Journal of Cardiothoracic and Vascular Anesthesia},
year = {2025},
volume = {39},
number = {1},
pages = {286--291},
doi = {10.1053/j.jvca.2024.10.020}
}