Kurz gefasst

Fallbericht in der Zeitschrift Texas Heart Institute Journal, 2025. Verfasst von Joshua R Hirsch und 3 weiteren Autor:innen. Beteiligte Einrichtung: Section of Cardiology, Baylor College of Medicine, Houston, Texas. Hauptthemen laut MEDLINE: Cardiac Pacing, Artificial, Electrophysiologic Techniques, Cardiac, Pacemaker, Artificial, Sick Sinus Syndrome. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The AVEIR DR (Abbott Medical) was the first dual-chamber leadless pacing system approved by the US Food and Drug Administration. Many patients with sinus node dysfunction have physiologically normal atrioventricular conduction, so an atrial-only pacing system may be appropriate for them. Three patients with symptomatic sinus node dysfunction underwent device implantation with electrophysiologic study, including incremental atrial pacing until loss of 1:1 atrioventricular conduction (atrioventricular Wenckebach cycle length) and His-ventricular interval measurement. If the atrioventricular Wenckebach cycle length was no more than 400 milliseconds and the His-ventricular interval measurement was no more than 55 milliseconds, single-chamber atrial implantation was deemed appropriate. Each patient displayed a different response to atrioventricular conduction testing, demonstrating how electrophysiologic study before device implantation may identify patients for whom atrial-only pacing is not appropriate.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cardiac Pacing, ArtificialElectrophysiologic Techniques, CardiacPacemaker, ArtificialSick Sinus SyndromeAgedHumansMaleMiddle AgedElectrocardiographyEquipment DesignHeart AtriaHeart Rate

Stichwörter der Autor:innen

Electrophysiologic techniques, cardiacbradycardiacardiac pacing, artificialsick sinus syndrome

Autor:innen und Institutionen

  • Section of Cardiology, Baylor College of Medicine, Houston, Texas.
  • Department of Cardiology, The Texas Heart Institute at Baylor St Luke's Medical Center, Houston, Texas.
  • Department of Cardiology, Michael E. DeBakey Veterans Affairs Medical Center, Houston, Texas.

Zitieren

APA

Hirsch, J. R., Gales, J. M., Giorgberidze, I., & Afshar, H. (2025). The Role of Electrophysiologic Study in Device Selection for Leadless Atrial Pacing. Texas Heart Institute Journal. https://doi.org/10.14503/thij-24-8495

Vancouver

Hirsch JR, Gales JM, Giorgberidze I, Afshar H. The Role of Electrophysiologic Study in Device Selection for Leadless Atrial Pacing. Texas Heart Institute Journal. 2025. doi:10.14503/thij-24-8495

BibTeX
@article{Hirsch2025,
  author = {Hirsch, Joshua R and Gales, Jordan M and Giorgberidze, Irakli and Afshar, Hamid},
  title = {The Role of Electrophysiologic Study in Device Selection for Leadless Atrial Pacing},
  journal = {Texas Heart Institute Journal},
  year = {2025},
  doi = {10.14503/thij-24-8495}
}
Kostenlos starten →