Different leadless pacemakers working in harmony (Aveir in the atrium/Micra AV2 in the ventricle) in a patient with dextrocardia and double outlet right ventricle after high‐risk infected device extraction
Journal of Cardiovascular Electrophysiology · 2024-03 · 35 (3) · 418-421
DOI: 10.1111/jce.16173 ↗Kurz gefasst
Fallbericht in der Zeitschrift Journal of Cardiovascular Electrophysiology, online erschienen am 11.01.2024. Verfasst von Carter English und 3 weiteren Autor:innen. Beteiligte Einrichtung: Pediatric and Adult Cardiology, UC Davis Medical Center, Sacramento, California, USA. Hauptthemen laut MEDLINE: Double Outlet Right Ventricle, Pacemaker, Artificial, Dextrocardia. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 6 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Introduction
Patients with congenital heart disease are at increased risk for requiring cardiac pacing during their lifetime.
Methods
We present the first described case of using two leadless pacing systems manufactured by separate companies implanted within the same patient to provide atrial and ventricular pacing due to complex congenital anatomy.
Results
A 27‐year‐old male with dextrocardia with double outlet right ventricle, subaortic ventricular septal defect, and pulmonary stenosis status‐post pulmonary valve replacement complicated by ventricular pacing dependence and subsequent atrial pacing dependence after atriotomy‐based atypical flutter ablation developed recurrent mediastinitis and pocket infection with erosion despite prolonged antibiotic treatment. Due to atrial and ventricular pacing dependence, a comprehensive congenital care team concluded the need for lead extraction and replacement of pacemaker via leadless peacemaking device. Laser‐lead extraction and temporary atrial pacemaker placement was performed. Afterward, a transesophageal echocardiogram guided implantation of both a Micra AV 2 (Medtronic) leadless pacemaker in the interventricular septum within the right ventricle and an Aveir (Abbott) leadless pacemaker in the superior base of the right atrial appendage was performed with successful pacing. Although there is no communication between these devices, atrial‐mechanical ventricular pacing was reliable with good implant thresholds, impedances and sensing from both devices.
Conclusion
Our case demonstrates the feasibility of using dual leadless pacing modalities to simultaneously pace someone at complex, prohibitive risk for temporary permanent or permanent pacemaker devices.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Pediatric and Adult Cardiology, UC Davis Medical Center, Sacramento, California, USA.
Zitieren
APA
English, C., Fan, D., Ing, F., & Cortez, D. (2024). Different leadless pacemakers working in harmony (Aveir in the atrium/Micra AV2 in the ventricle) in a patient with dextrocardia and double outlet right ventricle after high‐risk infected device extraction. Journal of Cardiovascular Electrophysiology, 35(3), 418-421. https://doi.org/10.1111/jce.16173
Vancouver
English C, Fan D, Ing F, Cortez D. Different leadless pacemakers working in harmony (Aveir in the atrium/Micra AV2 in the ventricle) in a patient with dextrocardia and double outlet right ventricle after high‐risk infected device extraction. Journal of Cardiovascular Electrophysiology. 2024;35(3):418-421. doi:10.1111/jce.16173
BibTeX
@article{English2024,
author = {English, Carter and Fan, Dali and Ing, Frank and Cortez, Daniel},
title = {Different leadless pacemakers working in harmony (Aveir in the atrium/Micra AV2 in the ventricle) in a patient with dextrocardia and double outlet right ventricle after high‐risk infected device extraction},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2024},
volume = {35},
number = {3},
pages = {418--421},
doi = {10.1111/jce.16173}
}
EUVIMED