EUVIMEDEUVIMED entdecken
Fallbericht

Use of transesophageal echocardiography guidance for pulmonary artery banding in a cat with ventricular septal defect

D N Acosta, S Sudunagunta, S Swift, S Goodrich, A Mathis, W Robinson, F Sarcinella

Journal of Veterinary Cardiology · 2026

DOI: 10.1016/j.jvc.2026.04.004 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Journal of Veterinary Cardiology, 2026. Verfasst von D N Acosta und 6 weiteren Autor:innen. Beteiligte Einrichtung: Willows Veterinary Centre & Referral Service, Highlands Road, West Midlands, B90 4NH, UK. Hauptthemen laut MEDLINE: Echocardiography, Transesophageal, Heart Septal Defects, Ventricular, Pulmonary Artery, Cat Diseases. Die Arbeit nennt 16 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pulmonary artery banding (PAB) is a long-term palliative treatment option for hemodynamically significant ventricular septal defects. The goal of PAB is to increase right ventricular afterload and consequently right ventricular systolic pressure, thereby reducing the interventricular pressure gradient and left-to-right systolic shunting flow. Historically, the guidelines for PAB have been formulated to reduce the pulmonary artery (PA) to approximately one-third of its original diameter. More recently, intra-operative monitoring techniques for assessing appropriate banding have been reported, such as intracardiac or distal PA pressure measurements, percentage of hemoglobin oxygen saturation assessment, and transthoracic or transesophageal echocardiography measurements. In this case report, transesophageal echocardiography was successfully used to assess the appropriate degree of banding of the PA in a cat with a hemodynamically significant ventricular septal defect by intra-operative monitoring of shunting flow velocities.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Echocardiography, TransesophagealHeart Septal Defects, VentricularPulmonary ArteryCat DiseasesAnimalsCats

Stichwörter der Autor:innen

Cardiac surgeryFeline congenital cardiac diseasePeri-operative hemodynamic monitoring

Autor:innen und Institutionen

  • Willows Veterinary Centre & Referral Service, Highlands Road, West Midlands, B90 4NH, UK.
  • Willows Veterinary Centre & Referral Service, Highlands Road, West Midlands, B90 4NH, UK. Electronic address: vet.fsarcinella@gmail.com.

Zitieren

APA

Acosta, D. N., Sudunagunta, S., Swift, S., Goodrich, S., Mathis, A., Robinson, W., & Sarcinella, F. (2026). Use of transesophageal echocardiography guidance for pulmonary artery banding in a cat with ventricular septal defect. Journal of Veterinary Cardiology. https://doi.org/10.1016/j.jvc.2026.04.004

Vancouver

Acosta DN, Sudunagunta S, Swift S, Goodrich S, Mathis A, Robinson W, et al. Use of transesophageal echocardiography guidance for pulmonary artery banding in a cat with ventricular septal defect. Journal of Veterinary Cardiology. 2026. doi:10.1016/j.jvc.2026.04.004

BibTeX
@article{Acosta2026,
  author = {Acosta, D N and Sudunagunta, S and Swift, S and Goodrich, S and Mathis, A and Robinson, W and Sarcinella, F},
  title = {Use of transesophageal echocardiography guidance for pulmonary artery banding in a cat with ventricular septal defect},
  journal = {Journal of Veterinary Cardiology},
  year = {2026},
  doi = {10.1016/j.jvc.2026.04.004}
}
Kostenlos starten →