EUVIMEDEUVIMED entdecken
BeobachtungsstudieVergleichsstudieOpen Access · CC BY 4.0

Haemodynamic monitoring after paediatric cardiac surgery using echocardiography and PiCCO

Fredrik Pernbro iD, Håkan Wåhlander, Birgitta Romlin

Cardiology in the Young · 2024

DOI: 10.1017/s1047951124026374 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Cardiology in the Young, 2024. Verfasst von Fredrik Pernbro und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Paediatric Anaesthesiology and Intensive Care, University of Gothenburg, Institute of Clinical Sciences, Gothenburg, Sweden. Hauptthemen laut MEDLINE: Cardiac Output, Cardiac Surgical Procedures, Echocardiography, Heart Septal Defects, Ventricular. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Haemodynamic instability is common after surgical repair of CHDs in infants and children. Monitoring cardiac output in addition to traditional circulation parameters could improve the postoperative care of these patients. Echocardiography and transpulmonary thermodilution are the two most common methods for measuring cardiac output in infants.

Objectives

To compare the results of cardiac output measurements using echocardiography and a transpulmonary thermodilution setup after paediatric cardiac surgery.

Methods

Forty children, scheduled for elective repair of a ventricular septal defect or of an atrio-ventricular septal defect using cardiopulmonary bypass, were enrolled in this prospective, observational study. Cardiac output was simultaneously measured using echocardiography and a commercially available transpulmonary thermodilution method (PiCCO™) at 18 h after the end of surgery.

Results

At 18 h after surgery, PiCCO™ gave a mean of 3.0% higher cardiac output than echocardiography. This difference was not statistically significant. 95% of the observations fell within –50.0 to 82.6%.

Conclusion

The methods were found to have a good agreement on average, with no statistically significant difference between them. However, the spread of the results was large. It is questionable whether the methods can be used interchangeably in clinical practice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cardiac OutputCardiac Surgical ProceduresEchocardiographyHeart Septal Defects, VentricularHemodynamic MonitoringHeart Septal Defects, AtrialHumansProspective StudiesInfantFemaleMaleChild, PreschoolThermodilutionChildHemodynamics

Stichwörter der Autor:innen

CHDsHaemodynamic monitoringechocardiographyheart surgerypaediatrictranspulmonary thermodilution

Autor:innen und Institutionen

  • Department of Paediatric Anaesthesiology and Intensive Care, University of Gothenburg, Institute of Clinical Sciences, Gothenburg, Sweden.
  • Department of Anaesthesiology and Intensive Care, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
  • Department of Cardiology, Queen Silvia's Children's Hospital, Gothenburg, Sweden.
  • Department of Paediatrics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.

ORCID-Profile: Fredrik Pernbro

Zitieren

APA

Pernbro, F., Wåhlander, H., & Romlin, B. (2024). Haemodynamic monitoring after paediatric cardiac surgery using echocardiography and PiCCO. Cardiology in the Young. https://doi.org/10.1017/s1047951124026374

Vancouver

Pernbro F, Wåhlander H, Romlin B. Haemodynamic monitoring after paediatric cardiac surgery using echocardiography and PiCCO. Cardiology in the Young. 2024. doi:10.1017/s1047951124026374

BibTeX
@article{Pernbro2024,
  author = {Pernbro, Fredrik and Wåhlander, Håkan and Romlin, Birgitta},
  title = {Haemodynamic monitoring after paediatric cardiac surgery using echocardiography and PiCCO},
  journal = {Cardiology in the Young},
  year = {2024},
  doi = {10.1017/s1047951124026374}
}
Kostenlos starten →