EUVIMEDEUVIMED entdecken
Vergleichsstudie

Lung Stereotactic Body Radiation Therapy Using Dynamic Conformal Arc Therapy With or Without Flattening Filter Photon Beam: A French Institutional Experience

Mickael Preault, Leonor Chaltiel, Jonathan Khalifa, Audrey Keller, Sarah Zahi, Audrey Rabeau, Laure Parent, Carole Massabeau

Practical Radiation Oncology · 2025

DOI: 10.1016/j.prro.2025.04.006 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Practical Radiation Oncology, 2025. Verfasst von Mickael Preault und 7 weiteren Autor:innen. Beteiligte Einrichtung: Radiation Department, Institut Claudius Regaud, IUCT-O, Toulouse, France. Hauptthemen laut MEDLINE: Radiosurgery, Radiotherapy, Conformal, Photons, Lung Neoplasms. Die Arbeit nennt 33 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To evaluate the safety and efficacy of the flattening filter-free (FFF) technique compared with the flattening filter (FF) technique in the context of lung tumor stereotactic body radiation therapy (SBRT). METHODS AND MATERIALS: The study included a total of 101 lung SBRT treatments among 82 consecutive patients. Patients were treated with an FF technique (FF group, n = 47) between 2012 and 2014 and with an FFF technique (FFF group, n = 54) between 2014 and 2016. Our risk-adapted SBRT fractionation protocol based on location (3 or 5 fractions) remained unchanged during the entire study. Treatment plans consisted of a dynamic conformal half-arc, and the dose was prescribed to the 80% isodose line. FFF treatments are delivered 2.33 times faster than FF treatments because of the higher dose rate of the machine. RESULTS: The median follow-up for the 82 patients was 55.4 months, and the median overall survival for all patients was 45.9 months. Local control at 2 years post-SBRT of the 101 lesions was excellent and similar in both groups (97.9% in the FF group vs 98.1% in the FFF group). There were no grade 4 or 5 toxicities and only 4 grade 3 lung toxicities (4.1%) in the FF group (vs none in the FFF group). Three patients in the FFF group versus 1 patient in the FF group had a symptomatic rib fracture. Among patients treated free breathing on a single lesion (n = 65), the local recurrence-free survival at 2 years was 85.7% (95% CI, 62.0-95.2) in the FFF group and 71.4% (95% CI, 52-84.1) in the FF group (P = .139). CONCLUSIONS: Patient treatment with lung SBRT using the FFF technique is safe and provides an excellent long-term local control and low toxicity compared with the FF technique.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadiosurgeryRadiotherapy, ConformalPhotonsLung NeoplasmsNeoplasm Recurrence, LocalFollow-Up StudiesWhole-Body IrradiationFour-Dimensional Computed TomographyRadiotherapy Planning, Computer-AssistedDose Fractionation, RadiationPositron-Emission TomographyBiopsyLungDisease-Free SurvivalHumansMaleFemaleAdultMiddle AgedAgedAged, 80 and overRetrospective Studies

Autor:innen und Institutionen

  • Radiation Department, Institut Claudius Regaud, IUCT-O, Toulouse, France.
  • Biostatistics Department, Institut Claudius Regaud, IUCT-O, Toulouse, France.
  • Pneumology Department, CH Larrey, Toulouse, France.
  • Engineering and Medical Physics, Institut Claudius Regaud, IUCT-O, Toulouse, France.
  • Radiation Department, Institut Claudius Regaud, IUCT-O, Toulouse, France. Electronic address: cmassabeau@hotmail.com.

Zitieren

APA

Preault, M., Chaltiel, L., Khalifa, J., Keller, A., Zahi, S., Rabeau, A., Parent, L., & Massabeau, C. (2025). Lung Stereotactic Body Radiation Therapy Using Dynamic Conformal Arc Therapy With or Without Flattening Filter Photon Beam: A French Institutional Experience. Practical Radiation Oncology. https://doi.org/10.1016/j.prro.2025.04.006

Vancouver

Preault M, Chaltiel L, Khalifa J, Keller A, Zahi S, Rabeau A, et al. Lung Stereotactic Body Radiation Therapy Using Dynamic Conformal Arc Therapy With or Without Flattening Filter Photon Beam: A French Institutional Experience. Practical Radiation Oncology. 2025. doi:10.1016/j.prro.2025.04.006

BibTeX
@article{Preault2025,
  author = {Preault, Mickael and Chaltiel, Leonor and Khalifa, Jonathan and Keller, Audrey and Zahi, Sarah and Rabeau, Audrey and Parent, Laure and Massabeau, Carole},
  title = {Lung Stereotactic Body Radiation Therapy Using Dynamic Conformal Arc Therapy With or Without Flattening Filter Photon Beam: A French Institutional Experience},
  journal = {Practical Radiation Oncology},
  year = {2025},
  doi = {10.1016/j.prro.2025.04.006}
}
Kostenlos starten →