Dosimetric robustness of tumor- and fiducial-based tracking in Radixact lung stereotactic body radiotherapy: a 4-dimensional CT-based simulation using imaging-derived tracking-error scenarios
British Journal of Radiology · 2026
DOI: 10.1093/bjr/tqag170 ↗Kurz gefasst
Fachartikel in der Zeitschrift British Journal of Radiology, 2026. Verfasst von Yugo Ebinuma und 9 weiteren Autor:innen. Beteiligte Einrichtung: Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo 113-8421, Japan. Hauptthemen laut MEDLINE: Lung Neoplasms, Radiosurgery, Four-Dimensional Computed Tomography, Fiducial Markers. Die Arbeit nennt 36 Literaturangaben.
Abstract (Originalsprache)
Objectives
To compare the dosimetry and robustness of 2 Radixact Synchrony lung stereotactic body radiotherapy (SBRT) tracking strategies: tumor-based lung tracking with respiratory modelling (LwR) and fiducial-based tracking with respiratory modelling (FwR).
Methods
Ten stage I non-small-cell lung cancer patients were retrospectively analyzed. SBRT plans (42 Gy in 4 fractions) were generated on maximum-exhalation computed tomography (CT) using planning target volumes (PTVs) created by 3-7 mm isotropic gross tumor volume (GTV) expansion. Each plan was mapped to all 4-dimensional CT (4DCT) phases via isocenter shifts from phase-specific GTV (LwR) or individual fiducial displacement (FwR). Deformable dose accumulation yielded LwR, nearest FwR, and farthest FwR simulated plans. GTV/PTV V100%, representative organ-at-risk (OAR) doses, and robustness versus target localization error, tumor-fiducial distance, and tumor volume were evaluated.
Results
With a 3-mm PTV margin, FwR showed larger losses in GTV coverage and PTV robustness than LwR (maximum decreases of 9.0% and 26.0%). FwR was less robust, particularly with unfavorable tumor-fiducial geometry. Larger PTV margins progressively mitigated FwR coverage degradation while maintaining acceptable OAR doses.
Conclusions
For lung SBRT delivered with Radixact Synchrony, LwR was more robust than FwR in this cohort, for which all tumor-fiducial distances exceeded 20 mm. When FwR is required, particularly under suboptimal tumor-fiducial geometry, a 3-mm margin should be used cautiously, and patient-specific evaluation of 5-7 mm margins within OAR dose constraints may be necessary. Advances in knowledge A 4DCT-based simulation using imaging-derived tracking-error scenarios reveals dosimetric robustness differences between LwR and FwR tracking.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo 113-8421, Japan.
- Department of Radiation Oncology, Graduate School of Medicine, Juntendo University, Bunkyo-ku, Tokyo 113-8421, Japan.
- Department of Medical Physics, Shonan Kamakura General Hospital, Kamakura City, Kanagawa 247-8533, Japan.
- Department of Radiation Oncology, Shonan Kamakura General Hospital, Kamakura City, Kanagawa 247-8533, Japan.
ORCID-Profile: Tatsuya Inoue, Jun Takatsu, Kotaro Iijima, Naoya Murakami
Zitieren
APA
Ebinuma, Y., Inoue, T., Shirata, R., Takatsu, J., Iijima, K., Yamano, A., Yagihashi, T., Minagawa, Y., Murakami, N., & Shikama, N. (2026). Dosimetric robustness of tumor- and fiducial-based tracking in Radixact lung stereotactic body radiotherapy: a 4-dimensional CT-based simulation using imaging-derived tracking-error scenarios. British Journal of Radiology. https://doi.org/10.1093/bjr/tqag170
Vancouver
Ebinuma Y, Inoue T, Shirata R, Takatsu J, Iijima K, Yamano A, et al. Dosimetric robustness of tumor- and fiducial-based tracking in Radixact lung stereotactic body radiotherapy: a 4-dimensional CT-based simulation using imaging-derived tracking-error scenarios. British Journal of Radiology. 2026. doi:10.1093/bjr/tqag170
BibTeX
@article{Ebinuma2026,
author = {Ebinuma, Yugo and Inoue, Tatsuya and Shirata, Ryosuke and Takatsu, Jun and Iijima, Kotaro and Yamano, Akihiro and Yagihashi, Takayuki and Minagawa, Yumiko and Murakami, Naoya and Shikama, Naoto},
title = {Dosimetric robustness of tumor- and fiducial-based tracking in Radixact lung stereotactic body radiotherapy: a 4-dimensional CT-based simulation using imaging-derived tracking-error scenarios},
journal = {British Journal of Radiology},
year = {2026},
doi = {10.1093/bjr/tqag170}
}
EUVIMED