Influence of number and location of implants and data acquisition device on the accuracy of an app-based extraoral photogrammetry and noncalibrated implant scan body system
The Journal of Prosthetic Dentistry · 2026-11 · 136 (5) · 1346-1357
DOI: 10.1016/j.prosdent.2026.08.016 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2026-11. Verfasst von Marta Revilla-León und 4 weiteren Autor:innen. Beteiligte Einrichtung: Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, …. Hauptthemen laut MEDLINE: Photogrammetry, Dental Implants, Mobile Applications. Die Arbeit nennt 49 Literaturangaben.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: The accuracy of complete arch implant scans is highly dependent on the implant scanning technique used to capture the implant positions. The influence of the number and location of implants and data acquisition device on the performance of the including app-based extraoral photogrammetry (PG) and noncalibrated implant scan body (ISB) systems remains unknown. PURPOSE: The purpose of this in vitro study was to assess the influence of the number and location of implants (4 in the anterior and posterior or 6 implants) and data acquisition device on the trueness and precision of complete arch scans captured using an app-based extraoral PG and noncalibrated ISB system. MATERIAL AND METHODS: A stone cast with 6 implant abutment analogs (MultiUnit Abutment) was obtained. A laboratory scan was used to obtain the reference file. Three groups were created based on the number of implants: 6, 4 posterior, and 4 anterior implants of the reference cast. Three subgroups were developed based on the implant scanning technique and acquisition device used to capture the scans: app-based (T-Marker) with a tablet (iPad) or a smartphone (iPhone), and a noncalibrated ISB system (IOConnect) with an intraoral scanner (IOS) (i900) (n=30). The reference and experimental scans were imported into a program (DentalCAD) to design an implant-supported bar. The designs were imported into another program (Geomagic) to measure the linear and angular distances among the implants. The measurements obtained from the reference file were used as a control to calculate the discrepancies for each specimen. Two-way ANOVA and post hoc pairwise comparison tests were used to analyze trueness. The Levene test was used to analyze precision (α=.05). RESULTS: Linear trueness discrepancies were found among the groups (P=.016) and subgroups (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; Faculty and Director of Research and Digital Dentistry, Kois Ce…
- Collaborating Professor of Postgraduate Specialist in Advanced in Implant-Prosthodontics, Department of Conservative Dentistry and Prosthodontics, School of Dentistry, Complutense University of Madrid (UCM), Madrid, Spa…
- Assistant Professor, Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, N.Y.
- Director, Kois Center, Seattle, Wash; Affiliate Professor, Graduate in Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; and Private practice, Seattle, W…
- Associate Professor, Department of Conservative Dentistry and Prosthodontics, School of Dentistry, Complutense University of Madrid (UCM), Madrid, Spain.
Zitieren
APA
Revilla-León, M., Cascos, R., Barmak, A. B., Kois, J. C., & Gómez-Polo, M. (2026). Influence of number and location of implants and data acquisition device on the accuracy of an app-based extraoral photogrammetry and noncalibrated implant scan body system. The Journal of Prosthetic Dentistry, 136(5), 1346-1357. https://doi.org/10.1016/j.prosdent.2026.08.016
Vancouver
Revilla-León M, Cascos R, Barmak AB, Kois JC, Gómez-Polo M. Influence of number and location of implants and data acquisition device on the accuracy of an app-based extraoral photogrammetry and noncalibrated implant scan body system. The Journal of Prosthetic Dentistry. 2026;136(5):1346-1357. doi:10.1016/j.prosdent.2026.08.016
BibTeX
@article{RevillaLen2026,
author = {Revilla-León, Marta and Cascos, Rocío and Barmak, Abdul B and Kois, John C and Gómez-Polo, Miguel},
title = {Influence of number and location of implants and data acquisition device on the accuracy of an app-based extraoral photogrammetry and noncalibrated implant scan body system},
journal = {The Journal of Prosthetic Dentistry},
year = {2026},
volume = {136},
number = {5},
pages = {1346--1357},
doi = {10.1016/j.prosdent.2026.08.016}
}
EUVIMED