Accuracy of a smartphone app and photogrammetry algorithm in complete arch digital implant capture: An in vivo comparative study
The Journal of Prosthetic Dentistry · 2026
DOI: 10.1016/j.prosdent.2025.11.020 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Journal of Prosthetic Dentistry, 2026. Verfasst von Andrea Santamaría-Laorden und 5 weiteren Autor:innen. Beteiligte Einrichtung: Assistant Professor, Universidad Europea de Madrid, Faculty of Biomedical and Health Sciences, Department of Dentistry, Madrid, Spain. Hauptthemen laut MEDLINE: Photogrammetry, Smartphone, Mobile Applications, Algorithms. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
STATEMENT OF PROBLEM: A photogrammetry algorithm integrated into a smartphone application has been proposed as an alternative to photogrammetry scanners for complete arch digital implant recording. Clinical studies, however, are lacking. PURPOSE: The purpose of this clinical study was to evaluate the accuracy of a photogrammetry app for complete arch prostheses supported by 6 implants. MATERIAL AND METHODS: A total of 8 participants with 10 completely edentulous arches with 6 multiunit implant abutments were recruited. For each participant, 5 recordings were made using a photogrammetry app (PIC app; Pic dental), and 1 recording with a photogrammetry device (PIC system; PIC dental). From the resulting standard tessellation language (STL) files, linear and angular Euclidean distances were recorded. A statistical analysis of the measurements obtained was used to determine their trueness and precision. The Shapiro-Wilk tests were run to analyse the trueness data, and the Levene test was used to assess the precision values (α=.05). RESULTS: The mean ±standard deviation absolute difference between the PIC system and PIC app was 21 ±16 µm and 0.20 ±0.17 degrees. The interimplant distance did not signifficantly affect linear trueness (P>.05) or angular trueness (P>.05). The arch type did affect linear trueness P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Assistant Professor, Universidad Europea de Madrid, Faculty of Biomedical and Health Sciences, Department of Dentistry, Madrid, Spain.
- Cathedratic Professor, Department of Conservative & Prosthetic Dentistry, Faculty of Dentistry, Complutense University of Madrid (UCM), Madrid, Spain. Electronic address: raquel.castillo@odon.ucm.es.
- Doctoral Student, Universidad Europea de Madrid, Faculty of Biomedical and Health Sciences, Department of Dentistry.
- Associate Professor, Universidad Europea de Madrid, Faculty of Biomedical and Health Sciences, Department of Veterinary Medicine, Madrid, Spain.
Zitieren
APA
Santamaría-Laorden, A., Castillo-Oyagüe, R., Martínez-Marugán, A., Sánchez, J. L. Q., Andreu-Vázquez, C., & Orejas-Pérez, J. (2026). Accuracy of a smartphone app and photogrammetry algorithm in complete arch digital implant capture: An in vivo comparative study. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2025.11.020
Vancouver
Santamaría-Laorden A, Castillo-Oyagüe R, Martínez-Marugán A, Sánchez JLQ, Andreu-Vázquez C, Orejas-Pérez J. Accuracy of a smartphone app and photogrammetry algorithm in complete arch digital implant capture: An in vivo comparative study. The Journal of Prosthetic Dentistry. 2026. doi:10.1016/j.prosdent.2025.11.020
BibTeX
@article{SantamaraLaorden2026,
author = {Santamaría-Laorden, Andrea and Castillo-Oyagüe, Raquel and Martínez-Marugán, Alicia and Sánchez, Jose Luis Quirós and Andreu-Vázquez, Cristina and Orejas-Pérez, Jaime},
title = {Accuracy of a smartphone app and photogrammetry algorithm in complete arch digital implant capture: An in vivo comparative study},
journal = {The Journal of Prosthetic Dentistry},
year = {2026},
doi = {10.1016/j.prosdent.2025.11.020}
}
EUVIMED