Accuracy of complete arch implant scans recorded by using intraoral and extraoral photogrammetry systems
The Journal of Prosthetic Dentistry · 2025-12 · 134 (6) · 2508-2514
DOI: 10.1016/j.prosdent.2025.01.041 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Journal of Prosthetic Dentistry, 2025-12. Verfasst von Marta Revilla-León und 5 weiteren Autor:innen. Beteiligte Einrichtung: Affiliate Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; Fac…. Hauptthemen laut MEDLINE: Photogrammetry, Dental Implants. Die Arbeit wurde bisher 39-mal zitiert (Crossref) und nennt 17 Literaturangaben.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Extraoral photogrammetry (PG) systems provide a reliable method for recording implant positions; however, the accuracy of an intraoral PG system integrated into an intraoral scanner (IOS) system remains unknown. PURPOSE: The purpose of this in vitro study was to compare the accuracy of complete arch implant scans captured by using 4 extraoral and 1 intraoral PG system. MATERIAL AND METHODS: An edentulous cast with 6 implant abutment analogs (MultiUnit Abutment Plus Replica) was digitized (T710). Five groups were created depending on the PG system used to capture complete arch implant scans: 4 extraoral PG systems, PIC (PIC System), Icam4D (Imetric), Grammee (BlueSkyBio), OxoFit (Oxo), and 1 intraoral PG device, Elite (Shining 3D) (n=30). In each group, the corresponding optical markers were placed on the implant abutment analogs of the reference cast, and 30 consecutive scans were recorded. Euclidean linear and angular measurements were obtained on the digitized reference cast and used to compare the discrepancies with the same measurements obtained on each experimental scan. One-way ANOVA and Tukey tests were used to analyze the trueness data. The Levene test was used to analyze precision values (α=.05). RESULTS: Significant linear trueness (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Affiliate Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; Faculty and Director, Research and Digital Dentistry, Kois Center, Seattl…
- Associate Professor, Department of Conservative Dentistry and Prosthodontics, School of Dentistry, Complutense University of Madrid (UCM), Madrid, Spain.
- Private practice, Valparaiso, Ind.
- Assistant Professor, Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, NY.
- Founder and Director, Kois Center, Seattle, Wash.; Affiliate Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; and Private practice,…
- Adjunct Professor, Department of Dental Medicine, Faculty of Medicine and Dentistry, University of Valencia (UV), Valencia, Spain.
Zitieren
APA
Revilla-León, M., Gómez-Polo, M., Drone, M., Barmak, A. B., Kois, J. C., & Alonso Pérez-Barquero, J. (2025). Accuracy of complete arch implant scans recorded by using intraoral and extraoral photogrammetry systems. The Journal of Prosthetic Dentistry, 134(6), 2508-2514. https://doi.org/10.1016/j.prosdent.2025.01.041
Vancouver
Revilla-León M, Gómez-Polo M, Drone M, Barmak AB, Kois JC, Alonso Pérez-Barquero J. Accuracy of complete arch implant scans recorded by using intraoral and extraoral photogrammetry systems. The Journal of Prosthetic Dentistry. 2025;134(6):2508-2514. doi:10.1016/j.prosdent.2025.01.041
BibTeX
@article{RevillaLen2025,
author = {Revilla-León, Marta and Gómez-Polo, Miguel and Drone, Michael and Barmak, Abdul B and Kois, John C and Alonso Pérez-Barquero, Jorge},
title = {Accuracy of complete arch implant scans recorded by using intraoral and extraoral photogrammetry systems},
journal = {The Journal of Prosthetic Dentistry},
year = {2025},
volume = {134},
number = {6},
pages = {2508--2514},
doi = {10.1016/j.prosdent.2025.01.041}
}