Intra Oral Photogrammetry: Trueness Evaluation of Novel Technology for Implant Complete‐Arch Digital Impression In Vitro
Clinical Implant Dentistry and Related Research · 2025
DOI: 10.1111/cid.70049 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Implant Dentistry and Related Research, 2025. Verfasst von Alessandro Pozzi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Science and Translational Medicine, University of Rome Tor Vergata, Rome, Italy. Hauptthemen laut MEDLINE: Photogrammetry, Dental Impression Technique, Dental Implants. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Objectives
To investigate the trueness of intraoral photogrammetry (IPG) technology for complete‐arch implant digital impression and evaluate the effect of implant number. Material and Methods All data were fully anonymized in compliance with ethical standards, and a total of 30 complete‐arch patient models with 4 ( n = 13), 5 ( n = 9), or 6 ( n = 8) implants were selected from the archive. Digital impressions were taken with IPG and a desktop scanner. Test and reference standard tessellation language (STL) files were superimposed using a best‐fit algorithm. For each implant position, mean linear (Δ X , Δ Y , Δ Z axes) and angular deviations (ΔANGLE) and three‐dimensional (3D) Euclidean distances (ΔEUC) were measured as primary outcomes with a dedicated software program (Hyper Cad S, Cam HyperMill, Open Mind Technologies) and reported as descriptive statistics. Secondary aim was to determine using linear mixed models whether implant number affected trueness. All statistical analyses were conducted using Stata 18 (Stata Corp, College Station) and significance was set at 0.05.
Results
A total of 30 definitive casts with 4 ( n = 13), 5 ( n = 8), and 6 ( n = 9) multi‐unit abutment (MUA) analogs were analyzed ( n = 146 implant positions). The mean deviations along the X ‐axis were −3.97 ± 32.8 μm, while along the Y ‐axis, they were −1.97 ± 25.03 μm. For the Z ‐axis, a greater deviation of −33 ± 34.77 μm was observed. The 3D Euclidean distance deviation measured 57.22 ± 27.41 μm, and the angular deviation was 0.26° ± 0.19°. Statistically significant deviations were experienced for Δ Z , ΔEUC, and ΔANGLE ( p < 0.01). Additionally, the number of implants had a statistically significant effect only on the Z ‐axis deviation ( p = 0.03).
Conclusions
Within study limitations, IPG technology was feasible for complete‐arch digital implant impression with mean linear, angular, and 3D deviations far below the acceptable range for a passive fit. Reported IPG trueness might avoid a rigid prototype try‐in. The implant number had no influence on trueness except for Z‐axis deviations. Integrating photogrammetry with intraoral optical scanning (IOS) improved practicality, optimizing the digital workflow. Further clinical trials are needed to confirm these findings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Clinical Science and Translational Medicine, University of Rome Tor Vergata, Rome, Italy.
- Goldstein Center for Esthetic and Implant Dentistry, Department of Restorative Sciences, The Dental College of Georgia at Augusta University, Augusta, Georgia, USA.
- Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Harbor, Michigan, USA.
- Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, Massachusetts, USA.
- Department of Chemical Science and Technologies, University of Rome Tor Vergata, Rome, Italy.
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland.
ORCID-Profile: Alessandro Pozzi, Luis Azevedo
Zitieren
APA
Pozzi, A., Laureti, A., Tawil, I., Chow, J., Azevedo, L., Fehmer, V., & Sailer, I. (2025). Intra Oral Photogrammetry: Trueness Evaluation of Novel Technology for Implant Complete‐Arch Digital Impression In Vitro. Clinical Implant Dentistry and Related Research. https://doi.org/10.1111/cid.70049
Vancouver
Pozzi A, Laureti A, Tawil I, Chow J, Azevedo L, Fehmer V, et al. Intra Oral Photogrammetry: Trueness Evaluation of Novel Technology for Implant Complete‐Arch Digital Impression In Vitro. Clinical Implant Dentistry and Related Research. 2025. doi:10.1111/cid.70049
BibTeX
@article{Pozzi2025,
author = {Pozzi, Alessandro and Laureti, Andrea and Tawil, Isaac and Chow, James and Azevedo, Luis and Fehmer, Vincent and Sailer, Irena},
title = {Intra Oral Photogrammetry: Trueness Evaluation of Novel Technology for Implant Complete‐Arch Digital Impression In Vitro},
journal = {Clinical Implant Dentistry and Related Research},
year = {2025},
doi = {10.1111/cid.70049}
}
EUVIMED