EUVIMEDEUVIMED entdecken
Vergleichsstudie

Clinical evaluation of complete arch implant scanning accuracy recorded using an app-based photogrammetry and noncalibrated scan body system

Marta Revilla-León, Rocío Cascos, Abdul B Barmak, John C Kois, Michael Drone, Miguel Gómez-Polo

The Journal of Prosthetic Dentistry · 2026

DOI: 10.1016/j.prosdent.2026.05.030 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The Journal of Prosthetic Dentistry, 2026. Verfasst von Marta Revilla-León und 5 weiteren Autor:innen. Beteiligte Einrichtung: Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, …. Hauptthemen laut MEDLINE: Photogrammetry, Dental Implants, Mobile Applications, Dental Arch. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 43 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: Implant positions can be recorded by using intraoral scanners (IOSs) or photogrammetry (PG) methods. Although the literature has assessed the accuracy of these scanning techniques, further investigation is needed as the technology continues to evolve. PURPOSE: The purpose of this in vivo study was to compare the accuracy of complete arch implant scans recorded by using a noncalibrated implant scan body (ISB) method (IOConnect) or an app-based PG (T-Marker). MATERIAL AND METHODS: A patient with 4 implants with 4 abutments (MultiUnit Abutment) participated in the study. A scan body was tightened into each implant abutment, and 3 scans were obtained (reference) using an extraoral PG (Micron Mapper). Two groups were developed based on the technique selected to record implant scans: a noncalibrated ISB system (IOConnect) and an app-based (T-Marker) PG. In the IOConnect group, an ISB was hand-tightened into each implant abutment followed by capture of the scans using an IOS (TRIOS 5). In the app-based group, a scan body (T-Marker scan body) was tightened into each implant abutment followed by recoding the scans using an app (T-Marker) and a tablet (iPad Pro). The average of the linear and angular measurements obtained among the 3 reference scans was used as a reference to calculate discrepancies with the same measurements obtained on each specimen. The independent samples t test was used to analyze trueness. The Levene test was used to analyze precision (α=.05). RESULTS: Significant differences were found among the linear (P=.023) and angular (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotogrammetryDental ImplantsMobile ApplicationsDental ArchHumansDental Abutments

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; Faculty and Director of Research and Digital Dentistry, Kois Ce…
  • Collaborating Professor of Postgraduate Specialist in Advanced in Implant-Prosthodontics, Department of Conservative Dentistry and Prosthodontics, School of Dentistry, Complutense University of Madrid (UCM), Madrid, Spa…
  • Assistant Professor, Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, N.Y.
  • Director, Kois Center, Seattle, Wash.; Affiliate Professor, Graduate in Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; and Private practice, Seattle,…
  • Private practice, Valparaiso, Ind.
  • Associate Professor, Department of Conservative Dentistry and Prosthodontics, School of Dentistry, Complutense University of Madrid (UCM), Madrid, Spain.

Zitieren

APA

Revilla-León, M., Cascos, R., Barmak, A. B., Kois, J. C., Drone, M., & Gómez-Polo, M. (2026). Clinical evaluation of complete arch implant scanning accuracy recorded using an app-based photogrammetry and noncalibrated scan body system. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2026.05.030

Vancouver

Revilla-León M, Cascos R, Barmak AB, Kois JC, Drone M, Gómez-Polo M. Clinical evaluation of complete arch implant scanning accuracy recorded using an app-based photogrammetry and noncalibrated scan body system. The Journal of Prosthetic Dentistry. 2026. doi:10.1016/j.prosdent.2026.05.030

BibTeX
@article{RevillaLen2026,
  author = {Revilla-León, Marta and Cascos, Rocío and Barmak, Abdul B and Kois, John C and Drone, Michael and Gómez-Polo, Miguel},
  title = {Clinical evaluation of complete arch implant scanning accuracy recorded using an app-based photogrammetry and noncalibrated scan body system},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2026},
  doi = {10.1016/j.prosdent.2026.05.030}
}
Kostenlos starten →