EUVIMEDEUVIMED entdecken
Vergleichsstudie

Capturing complete arch implant positions in two partial photogrammetry scans: Does it impact the accuracy of complete arch implant scans?

Marta Revilla-León, Abdul B Barmak, Michael Drone, John C Kois, Jorge Alonso Pérez-Barquero

The Journal of Prosthetic Dentistry · 2025

DOI: 10.1016/j.prosdent.2025.02.024 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The Journal of Prosthetic Dentistry, 2025. Verfasst von Marta Revilla-León und 4 weiteren Autor:innen. Beteiligte Einrichtung: Affiliate Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; Fac…. Hauptthemen laut MEDLINE: Photogrammetry, Dental Implants. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 15 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: Extraoral photogrammetry (PG) systems can record implant positions in 1 scan or in 2 scans that are then merged. However, the accuracy of implant positions recorded in 2 partial photogrammetry scans is unknown. PURPOSE: The purpose of this in vitro study was to compare the accuracy of complete arch implant scans recorded in 1 or 2 scans by using 3 extraoral PG systems. MATERIAL AND METHODS: An edentulous cast with 6 implant abutment analogs (MultiUnit Abutment Plus Replica) was digitized (T710). Two groups were developed depending on the number of scans recorded to capture the 6 implant positions: 1 or 2 scans (n=30). Additionally, 3 subgroups were created based on the PG used: Icam4D, Grammee, OxoFit. In the 1-scan group, the corresponding markers of each system were placed on the implant abutment analogs of the cast. On each specimen, a scan was recorded to capture the 6 implant positions. In the 2-scan group, the corresponding markers of each system were hand tightened on the implant abutment analogs located on the right and left first molars and right and left lateral incisors. The first PG scan was obtained to capture these 4 implant positions. Afterwards, the markers of the right and left lateral incisors were removed and hand tightened on the implant abutment analogs positioned on the right and left first premolars. Lastly, the second PG scan was obtained to capture these 4 implant positions. In the ICam4D and Grammee subgroups, the partial scans were merged by the PG software program. In the OxoFit subgroup, the partial PG scans were merged by using a program (DentalCAD). Linear and angular measurements among the implants were completed on the digitized cast and used to compare the discrepancies with the same measurements acquired on each specimen. Two-way ANOVA and Tukey tests were used to analyze the trueness data. The Levene test was used to analyze the precision values (α=.05). RESULTS: Linear trueness differences were found among the groups (P=.048) and subgroups (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotogrammetryDental ImplantsHumansIn Vitro TechniquesDental Abutments

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Affiliate Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; Faculty and Director, Research and Digital Dentistry, Kois Center, Seattl…
  • Assistant Professor, Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, NY.
  • Private practice, Valparaiso, Ind.
  • Founder and Director, Kois Center, Seattle, Wash.; Affiliate Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; and Private practice,…
  • Adjunct Professor, Department of Dental Medicine, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain.

Zitieren

APA

Revilla-León, M., Barmak, A. B., Drone, M., Kois, J. C., & Alonso Pérez-Barquero, J. (2025). Capturing complete arch implant positions in two partial photogrammetry scans: Does it impact the accuracy of complete arch implant scans?. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2025.02.024

Vancouver

Revilla-León M, Barmak AB, Drone M, Kois JC, Alonso Pérez-Barquero J. Capturing complete arch implant positions in two partial photogrammetry scans: Does it impact the accuracy of complete arch implant scans?. The Journal of Prosthetic Dentistry. 2025. doi:10.1016/j.prosdent.2025.02.024

BibTeX
@article{RevillaLen2025,
  author = {Revilla-León, Marta and Barmak, Abdul B and Drone, Michael and Kois, John C and Alonso Pérez-Barquero, Jorge},
  title = {Capturing complete arch implant positions in two partial photogrammetry scans: Does it impact the accuracy of complete arch implant scans?},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2025},
  doi = {10.1016/j.prosdent.2025.02.024}
}