EUVIMEDEUVIMED entdecken
Crossref

Accuracy of implant scans recorded using tablet-based photogrammetry and noncalibrated implant scan body systems

Marta Revilla-León, Miguel Gómez-Polo, Abdul B Barmak, John C Kois, Jorge Alonso Pérez-Barquero

The Journal of Prosthetic Dentistry · 2026

DOI: 10.1016/j.prosdent.2026.03.034 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2026. Verfasst von Marta Revilla-León und 4 weiteren Autor:innen. Beteiligte Einrichtung: Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, …. Hauptthemen laut MEDLINE: Photogrammetry, Dental Implants. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 33 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: The accuracy of implant scans varies depending on the scanning technique used. Newest developments include the capability to capture implant positions by using tablet-based photogrammetry (PG). However, the accuracy of this scanning technique remains unknown. PURPOSE: The purpose of this in vitro study was to analyze the accuracy of complete arch implant scans captured using a tablet-based PG and a noncalibrated implant scan body (ISB) system. MATERIAL AND METHODS: A stone cast with 6 implant abutment analogs (MultiUnit Abutment Plus Replica) was digitized by using a laboratory scanner (T710) (control scan). Two groups were created depending on the scanning technique used to capture the experimental complete arch implant scans: tablet-based PG (T-Marker) (Tablet-PG group) and noncalibrated ISB system (IOConnect) (NC-ISB group) (n=30). In the Tablet-PG group, an optical marker was hand tightened into each implant abutment of the reference stone cast. Then, consecutive scans were captured by using a tablet (iPad Pro) and following the scanning distance and pattern recommended by the manufacturer. In the NC-ISB group, a noncalibrated ISB was hand tightened into each implant abutment toward the center of the arch, as instructed by the manufacturer. Consecutive scans involving the distal geometry of the noncalibrated ISBs were recorded using an IOS (TRIOS 5). Euclidean linear and angular measurements were obtained on the control scan and used to compare the discrepancies with the same measurements obtained on each experimental scan. The independent samples t test was used to analyze the trueness data. The Levene test was used to analyze the precision values (α=.05). RESULTS: Significant differences were found among the overall linear (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotogrammetryDental ImplantsHumansIn Vitro TechniquesDental Abutments

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; Faculty and Director of Research and Digital Dentistry, Kois Ce…
  • Associate Professor, Department of Conservative Dentistry and Prosthodontics, School of Dentistry, Complutense University of Madrid (UCM), Madrid, Spain.
  • Assistant Professor, Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, N.Y.
  • Director, Kois Center, Seattle, Wash.; Affiliate Professor, Graduate in Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; and Private practice, Seattle,…
  • Adjunct Professor, Department of Dental Medicine, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain.

Zitieren

APA

Revilla-León, M., Gómez-Polo, M., Barmak, A. B., Kois, J. C., & Alonso Pérez-Barquero, J. (2026). Accuracy of implant scans recorded using tablet-based photogrammetry and noncalibrated implant scan body systems. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2026.03.034

Vancouver

Revilla-León M, Gómez-Polo M, Barmak AB, Kois JC, Alonso Pérez-Barquero J. Accuracy of implant scans recorded using tablet-based photogrammetry and noncalibrated implant scan body systems. The Journal of Prosthetic Dentistry. 2026. doi:10.1016/j.prosdent.2026.03.034

BibTeX
@article{RevillaLen2026,
  author = {Revilla-León, Marta and Gómez-Polo, Miguel and Barmak, Abdul B and Kois, John C and Alonso Pérez-Barquero, Jorge},
  title = {Accuracy of implant scans recorded using tablet-based photogrammetry and noncalibrated implant scan body systems},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2026},
  doi = {10.1016/j.prosdent.2026.03.034}
}
Kostenlos starten →