Accuracy of intraoral photogrammetry and influence of calibrated implant scan body dimensions
The Journal of Prosthetic Dentistry · 2026
DOI: 10.1016/j.prosdent.2026.05.006 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Journal of Prosthetic Dentistry, 2026. Verfasst von Marta Revilla-León und 5 weiteren Autor:innen. Beteiligte Einrichtung: Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, Schoolof Dentistry, University of Washington, Seattle, W…. Hauptthemen laut MEDLINE: Photogrammetry, Dental Implants. Die Arbeit nennt 47 Literaturangaben.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: The accuracy of implant positions captured by intraoral scanners (IOSs) is highly dependent on the scanning technique selected. A recently introduced intraoral photogrammetry (PG) system is available; however, its accuracy remains unknown. PURPOSE: The purposes of this in vitro study were to compare the accuracy of complete arch implant scans recorded by using a nonsplinting technique and a new commercially available intraoral PG (Freedom Air) and evaluate the influence of calibrated ISB dimension (short and long) on the accuracy of the intraoral PG system. MATERIAL AND METHODS: A maxillary stone cast with 6 implant abutment analogs (MultiUnit Abutment Replica) was scanned using a laboratory scanner (T710) to obtain the control scan. Three groups were created based on the scanning technique selected to record complete arch implant scans by using an IOS (Freedom Air): standard ISBs (ISB group), short (S-IPG group) and long (L-IPG group) calibrated ISBs for intraoral PG (n=30). In the ISB group, a standard ISB (AB-SR-01 IPD) was tightened on each implant abutment. Then, scans were obtained by using the selected IOS. The standard ISBs were then retrieved. In the S-IPG group, a short ISB for intraoral PG (SQ-Type) was tightened into each implant abutment, follow by the acquisition of scans using the specific scanning tip for intraoral PG of the IOS device. Afterwards, the 2 ISBs of the first molar positions were retrieved. In the L-IPG group, a long calibrated ISB for intraoral PG (L-Type) was tightened into the 2 implant abutments of the first molar positions. Lastly, implant scans were recorded using the intraoral PG scanning tip of the IOS. Euclidean linear and angular measurements were computed among the 6 implants. The measurements acquired in the control scan were used to measure discrepancies with each experimental scan. One-way ANOVA and Tukey tests were used to analyze trueness. The Levene test was used to examine precision (α=.05). RESULTS: Linear trueness (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, Schoolof Dentistry, University of Washington, Seattle, Wash.; Faculty and Director of Research and Digital Dentistry, Kois Cen…
- Collaborating Professor of Postgraduate Specialist in Advanced in Implant-Prosthodontics, Department of Conservative Dentistry and Prosthodontics, School of Dentistry, Complutense University of Madrid (UCM), Madrid, Spa…
- Assistant Professor, Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, N.Y.
- Director, Kois Center, Seattle, Wash; Affiliate Professor, Graduate in Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; and Private practice, Seattle, W…
- Adjunct Professor, Department of Dental Medicine, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain.
- Associate Professor, Department of Conservative Dentistry and Prosthodontics, School of Dentistry, Complutense University of Madrid (UCM), Madrid, Spain.
Zitieren
APA
Revilla-León, M., Cascos, R., Barmak, A. B., Kois, J. C., Pérez-Barquero, J. A., & Gómez-Polo, M. (2026). Accuracy of intraoral photogrammetry and influence of calibrated implant scan body dimensions. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2026.05.006
Vancouver
Revilla-León M, Cascos R, Barmak AB, Kois JC, Pérez-Barquero JA, Gómez-Polo M. Accuracy of intraoral photogrammetry and influence of calibrated implant scan body dimensions. The Journal of Prosthetic Dentistry. 2026. doi:10.1016/j.prosdent.2026.05.006
BibTeX
@article{RevillaLen2026,
author = {Revilla-León, Marta and Cascos, Rocio and Barmak, Abdul B and Kois, John C and Pérez-Barquero, Jorge Alonso and Gómez-Polo, Miguel},
title = {Accuracy of intraoral photogrammetry and influence of calibrated implant scan body dimensions},
journal = {The Journal of Prosthetic Dentistry},
year = {2026},
doi = {10.1016/j.prosdent.2026.05.006}
}
EUVIMED