Effects of rapid infrared radiation heating on the warping deformation and mechanical properties of selective laser melted Co-Cr dental alloy
The Journal of Prosthetic Dentistry · 2025
DOI: 10.1016/j.prosdent.2024.12.013 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2025. Verfasst von Yanan Zhou und 6 weiteren Autor:innen. Beteiligte Einrichtung: Lecturer, School of Mechanical Engineering, Shandong University of Technology, Zibo, PR China. Electronic address: zhouyanan_0505@163.com. Hauptthemen laut MEDLINE: Infrared Rays, Lasers, Chromium Alloys, Dental Alloys. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 23 Literaturangaben.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Infrared radiation heating (IRH) technology has been innovatively applied to the annealing of selective laser melted (SLM) cobalt chromium (Co-Cr) frameworks. However, previous studies have not reported the effects of IRH on the warping deformation and mechanical properties of these frameworks. PURPOSE: The purpose of this in vitro study was to investigate the effects of IRH on the warping deformation and mechanical properties of dental SLM Co-Cr alloy and to evaluate its potential applications in dental restorations. MATERIAL AND METHODS: Two types of specimens, bone-shaped tensile specimens and warping deformation specimens (cantilever beam structures), were fabricated by SLM, followed by annealing using IRH and general furnace heating (GFH). The specimens were divided into 4 groups (n=6) based on the applied heat treatment method and build direction (IRH-XY; IRH-Z; GFH-XY; GFH-Z). The cantilever beam support structure of the warping deformation specimen was cut using wire cutting, and the warping deformation was measured using a digital image correlation optical extensometer. Tensile tests were used to evaluate mechanical properties, with the fracture characteristics being observed using a scanning electron microscope (SEM). A micro-Vickers hardness tester was used to measure the microhardness. The microstructures were analyzed using a metallographic microscope. All data were analyzed using a 1-way ANOVA and the Tukey Honestly Significant Difference test (α=.05). RESULTS: The surfaces of the SLM Co-Cr warping deformation specimens treated with IRH showed slight oxidation, while those treated with GFH exhibited a dark black appearance. No significant difference was found in deformation between the IRH group (0.412 ±0.039 mm) and the GFH group (0.379 ±0.070 mm) (P>.05). The elongation of the longitudinally built specimens was significantly higher than that of their transversely built counterparts (P .05). IRH treatment resulted in finer grains in the SLM Co-Cr alloy. Many fine second-phase particles precipitated from the matrix in the longitudinally built specimens, while few were observed in the transversely built specimens. CONCLUSIONS: The SLM Co-Cr specimens treated with IRH achieved comparable warping deformation and mechanical properties with those of the GFH-treated specimens. The IRH technology holds great potential for application to dental restorations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Lecturer, School of Mechanical Engineering, Shandong University of Technology, Zibo, PR China. Electronic address: zhouyanan_0505@163.com.
- Undergraduate student, School of Mechanical Engineering, Shandong University of Technology, Zibo, PR China.
- Postgraduate student, School of Mechanical Engineering, Shandong University of Technology, Zibo, PR China.
- Engineer, 3D Printing Medical Engineering Technology Center, SHINVA Medical Instrument Co., LTD., Zibo, PR China.
- Engineer, Department of Material Analysis and Testing, Wuxi Allgood Testing Service Co., LTD., Wuxi, PR China.
- Assistant Engineer, Human Resources Department, SHINVA Medical Instrument Co., LTD., Zibo, PR China.
Zitieren
APA
Zhou, Y., Liu, Z., Du, H., Jiang, J., Li, J., Ma, X., & Yi, Y. (2025). Effects of rapid infrared radiation heating on the warping deformation and mechanical properties of selective laser melted Co-Cr dental alloy. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2024.12.013
Vancouver
Zhou Y, Liu Z, Du H, Jiang J, Li J, Ma X, et al. Effects of rapid infrared radiation heating on the warping deformation and mechanical properties of selective laser melted Co-Cr dental alloy. The Journal of Prosthetic Dentistry. 2025. doi:10.1016/j.prosdent.2024.12.013
BibTeX
@article{Zhou2025,
author = {Zhou, Yanan and Liu, Zhihao and Du, Huwei and Jiang, Jie and Li, Jianxin and Ma, Xiaoyu and Yi, Yunchao},
title = {Effects of rapid infrared radiation heating on the warping deformation and mechanical properties of selective laser melted Co-Cr dental alloy},
journal = {The Journal of Prosthetic Dentistry},
year = {2025},
doi = {10.1016/j.prosdent.2024.12.013}
}
EUVIMED