Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2026. Verfasst von Julius Åkesson und 8 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Translational Cardiovascular Imaging, Institute of Cardiovascular Science, University College London, London, United Kingdom; Clinical Phy…. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Heart. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Svenska Sällskapet för Medicinsk Forskning, Swedish Research Council, UK Research and Innovation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Real-time (RT) bSSFP MRI enables fast free-breathing cardiovascular imaging but requires 10-16 slices for functional assessment, resulting in prolonged scan times. Simultaneous multi-slice (SMS) imaging can reduce acquisition time but when combined with non-Cartesian trajectories, it relies on iterative reconstructions that often preclude online use. This study investigates deep artifact suppression to facilitate rapid, online reconstruction of RT-SMS. METHODS: A spiral bSSFP RT sequence with SMS-2 was implemented at 1.5 T. Reconstruction used slice separation in k-space, followed by deep artifact suppression in image space using a 3D U-Net. Ten healthy volunteers were prospectively imaged. RT-SMS image quality and reconstruction time were compared between deep artifact suppression and compressed sensing (CS) reconstructions. Left (LV) and right (RV) ventricular volumes at end-diastole (EDV) and end-systole (ESV) and LV mass (LVM) were compared between RT-SMS with deep artifact suppression and reference-standard breath-hold (BH) imaging. RESULTS: The RT-SMS technique acquired each SMS slice-pair within a single cardiac cycle, reducing the total acquisition by ∼13× compared with BH imaging (15 s vs 3 min 15 s). Total reconstruction for RT-SMS using deep artifact suppression took ∼30 s, compared with 24 min 55 s for compressed sensing. Deep artifact suppression consistently outperformed CS in quantitative and qualitative image quality (p < 0.001). Functional agreement between BH and RT-SMS with deep artifact suppression was good (LVEDV: -7.5 ± 6.8 ml, LVESV: -0.9 ± 4.2 ml, RVEDV: -6.4 ± 8.4 ml, RVESV: 0.2 ± 10.7 ml, LVM: -10.3 ± 11.0 g). CONCLUSION: Online deep artifact suppression reconstruction for RT-SMS bSSFP CMR enables free-breathing short-axis coverage with a substantial reduction in acquisition and reconstruction time while maintaining diagnostic image quality.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Image Processing, Computer-AssistedMagnetic Resonance ImagingHeartHumansArtifactsAlgorithmsFemaleMaleAdultBreath HoldingHealthy VolunteersProspective StudiesRespirationMagnetic Resonance Imaging, Cine

Stichwörter der Autor:innen

Deep learning artifact suppressionReal-time MRISimultaneous multi-slice imagingSpiral bSSFP

Autor:innen und Institutionen

  • Centre for Translational Cardiovascular Imaging, Institute of Cardiovascular Science, University College London, London, United Kingdom; Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Skåne…
  • Research & Collaborations GBI, Siemens Healthcare Ltd, Camberley, United Kingdom.
  • Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund, Sweden; Department of Biomedical Engineering, Faculty of Engineering, Lund University, Lund, Sweden.
  • Centre for Translational Cardiovascular Imaging, Institute of Cardiovascular Science, University College London, London, United Kingdom.
  • Centre for Translational Cardiovascular Imaging, Institute of Cardiovascular Science, University College London, London, United Kingdom. Electronic address: jennifer.steeden@ucl.ac.uk.

Förderung

  • Svenska Sällskapet för Medicinsk Forskning
  • Swedish Research Council
  • UK Research and Innovation
  • Region Skåne

Zitieren

APA

Åkesson, J., Dragonu, I., Heiberg, E., Yao, T., Baker, R., Virsinskaite, R., Knight, D., Muthurangu, V., & Steeden, J. (2026). Rapid online deep artifact suppression for real-time spiral bSSFP CMR with blipped-CAIPI simultaneous multi-slice imaging at 1.5 T. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2026.110751

Vancouver

Åkesson J, Dragonu I, Heiberg E, Yao T, Baker R, Virsinskaite R, et al. Rapid online deep artifact suppression for real-time spiral bSSFP CMR with blipped-CAIPI simultaneous multi-slice imaging at 1.5 T. Magnetic Resonance Imaging. 2026. doi:10.1016/j.mri.2026.110751

BibTeX
@article{kesson2026,
  author = {Åkesson, Julius and Dragonu, Iulius and Heiberg, Einar and Yao, Tina and Baker, Rebecca and Virsinskaite, Ruta and Knight, Daniel and Muthurangu, Vivek and Steeden, Jennifer},
  title = {Rapid online deep artifact suppression for real-time spiral bSSFP CMR with blipped-CAIPI simultaneous multi-slice imaging at 1.5 T},
  journal = {Magnetic Resonance Imaging},
  year = {2026},
  doi = {10.1016/j.mri.2026.110751}
}
Kostenlos starten →