EUVIMEDEUVIMED entdecken
Crossref

Deep-learning reconstruction for noise reduction in respiratory-triggered single-shot phase sensitive inversion recovery myocardial delayed enhancement cardiac magnetic resonance

Maxine Tang, Haonan Wang, Shuo Wang, Eisha Wali, Joseph Gutbrod, Amita Singh, Luis Landeras, Martin A Janich, Victor Mor-Avi, Amit R Patel, Hena Patel

Magnetic Resonance Imaging · 2025

DOI: 10.1016/j.mri.2025.110460 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2025. Verfasst von Maxine Tang und 10 weiteren Autor:innen. Beteiligte Einrichtung: Northwestern Medicine, Chicago, IL, United States of America. Hauptthemen laut MEDLINE: Deep Learning, Heart, Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 15 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Phase-sensitive inversion recovery late gadolinium enhancement (LGE) improves tissue contrast, however it is challenging to combine with a free-breathing acquisition. Deep-learning (DL) algorithms have growing applications in cardiac magnetic resonance imaging (CMR) to improve image quality. We compared a novel combination of a free-breathing single-shot phase-sensitive LGE with respiratory triggering (FB-PS) sequence with DL noise reduction reconstruction algorithm to a conventional segmented phase-sensitive LGE acquired during breath holding (BH-PS). METHODS: 61 adult subjects (29 male, age 51 ± 15) underwent clinical CMR (1.5 T) with the FB-PS sequence and the conventional BH-PS sequence. DL noise reduction was incorporated into the image reconstruction pipeline. Qualitative metrics included image quality, artifact severity, diagnostic confidence. Quantitative metrics included septal-blood border sharpness, LGE sharpness, blood-myocardium apparent contrast-to-noise ratio (CNR), LGE-myocardium CNR, LGE apparent signal-to-noise ratio (SNR), and LGE burden. The sequences were compared via paired t-tests. RESULTS: 27 subjects had positive LGE. Average time to acquire a slice for FB-PS was 4-12 s versus ∼32-38 s for BH-PS (including breath instructions and break time in between breath hold). FB-PS with medium DL noise reduction had better image quality (FB-PS 3.0 ± 0.7 vs. BH-PS 1.5 ± 0.6, p < 0.0001), less artifact (4.8 ± 0.5 vs. 3.4 ± 1.1, p < 0.0001), and higher diagnostic confidence (4.0 ± 0.6 vs. 2.6 ± 0.8, p < 0.0001). Septum sharpness in FB-PS with DL reconstruction versus BH-PS was not significantly different. There was no significant difference in LGE sharpness or LGE burden. FB-PS had superior blood-myocardium CNR (17.2 ± 6.9 vs. 16.4 ± 6.0, p = 0.040), LGE-myocardium CNR (12.1 ± 7.2 vs. 10.4 ± 6.6, p = 0.054), and LGE SNR (59.8 ± 26.8 vs. 31.2 ± 24.1, p < 0.001); these metrics further improved with DL noise reduction. CONCLUSION: A FB-PS sequence shortens scan time by over 5-fold and reduces motion artifact. Combined with a DL noise reduction algorithm, FB-PS provides better or similar image quality compared to BH-PS. This is a promising solution for patients who cannot hold their breath.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningHeartMagnetic Resonance ImagingImage Processing, Computer-AssistedHumansMaleFemaleMiddle AgedAdultSignal-To-Noise RatioAlgorithmsContrast MediaArtifactsAgedBreath HoldingImage EnhancementGadoliniumMyocardiumRespirationImage Interpretation, Computer-Assisted

Stichwörter der Autor:innen

Cardiac magnetic resonance imagingDeep-learning noise reductionLate gadolinium enhancement imagingRespiratory-triggered

Substanzen

Contrast MediaGadolinium

Autor:innen und Institutionen

  • Northwestern Medicine, Chicago, IL, United States of America.
  • GE HealthCare, Waukesha, WI, United States of America.
  • University of Virginia, VA, United States of America.
  • NorthShore University Health System, Evanston, IL, United States of America.
  • Washington University School of Medicine, St. Louis, MO, United States of America.
  • Northwestern Medicine Central DuPage Hospital, Chicago, IL, United States of America.

Zitieren

APA

Tang, M., Wang, H., Wang, S., Wali, E., Gutbrod, J., Singh, A., Landeras, L., Janich, M. A., Mor-Avi, V., Patel, A. R., & Patel, H. (2025). Deep-learning reconstruction for noise reduction in respiratory-triggered single-shot phase sensitive inversion recovery myocardial delayed enhancement cardiac magnetic resonance. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2025.110460

Vancouver

Tang M, Wang H, Wang S, Wali E, Gutbrod J, Singh A, et al. Deep-learning reconstruction for noise reduction in respiratory-triggered single-shot phase sensitive inversion recovery myocardial delayed enhancement cardiac magnetic resonance. Magnetic Resonance Imaging. 2025. doi:10.1016/j.mri.2025.110460

BibTeX
@article{Tang2025,
  author = {Tang, Maxine and Wang, Haonan and Wang, Shuo and Wali, Eisha and Gutbrod, Joseph and Singh, Amita and Landeras, Luis and Janich, Martin A and Mor-Avi, Victor and Patel, Amit R and Patel, Hena},
  title = {Deep-learning reconstruction for noise reduction in respiratory-triggered single-shot phase sensitive inversion recovery myocardial delayed enhancement cardiac magnetic resonance},
  journal = {Magnetic Resonance Imaging},
  year = {2025},
  doi = {10.1016/j.mri.2025.110460}
}
Kostenlos starten →