Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Haiyang Chen und 5 weiteren Autor:innen. Beteiligte Einrichtung: National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shangha…. Hauptthemen laut MEDLINE: Algorithms, Heart, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: Shanghai Science and Technology Commission, National Natural Science Foundation of China.
Abstract (Originalsprache)
Purpose
To develop a model‐based motion correction (MoCo) method that does not need an analytical signal model to improve the quality of cardiac multi‐parametric mapping.
Methods
The proposed method constructs a hybrid loss that includes a dictionary‐matching loss and a signal low‐rankness loss, where the former registers the multi‐contrast original images to a set of motion‐free synthetic images and the latter forces the deformed images to be spatiotemporally coherent. We compared the proposed method with non‐MoCo, a pairwise registration method (Pairwise‐MI), and a groupwise registration method (pTVreg) via a free‐breathing Multimapping dataset of 15 healthy subjects, both quantitatively and qualitatively.
Results
The proposed method achieved the lowest contour tracking errors (epicardium: 2.00 ± 0.39 mm vs 4.93 ± 2.29 mm, 3.50 ± 1.26 mm, and 2.61 ± 1.00 mm, and endocardium: 1.84 ± 0.34 mm vs 4.93 ± 2.40 mm, 3.43 ± 1.27 mm, and 2.55 ± 1.09 mm for the proposed method, non‐MoCo, Pairwise‐MI, and pTVreg, respectively; all p < 0.01) and the lowest dictionary matching errors among all methods. The proposed method also achieved the highest scores on the visual quality of mapping (T1: 4.74 ± 0.33 vs 2.91 ± 0.82, 3.58 ± 0.87, and 3.97 ± 1.05, and T2: 4.48 ± 0.56 vs 2.59 ± 0.81, 3.56 ± 0.93, and 4.14 ± 0.80 for the proposed method, non‐MoCo, Pairwise‐MI, and pTVreg, respectively; all p < 0.01). Finally, the proposed method had similar T1 and T2 mean values and SDs relative to the breath‐hold reference in nearly all myocardial segments, whereas all other methods led to significantly different T1 and T2 measures and increases of SDs in multiple segments.
Conclusion
The proposed method significantly improves the motion correction accuracy and mapping quality compared with non‐MoCo and alternative image‐based methods.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
ORCID-Profile: Haiyang Chen, Yixin Emu, Zhuo Chen, Chenxi Hu
Förderung
- Shanghai Science and Technology Commission
- National Natural Science Foundation of China
Zitieren
APA
Chen, H., Emu, Y., Gao, J., Chen, Z., Aburas, A., & Hu, C. (2025). Retrospective motion correction for cardiac multi‐parametric mapping with dictionary matching‐based image synthesis and a low‐rank constraint. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30291
Vancouver
Chen H, Emu Y, Gao J, Chen Z, Aburas A, Hu C. Retrospective motion correction for cardiac multi‐parametric mapping with dictionary matching‐based image synthesis and a low‐rank constraint. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30291
BibTeX
@article{Chen2025,
author = {Chen, Haiyang and Emu, Yixin and Gao, Juan and Chen, Zhuo and Aburas, Ahmed and Hu, Chenxi},
title = {Retrospective motion correction for cardiac multi‐parametric mapping with dictionary matching‐based image synthesis and a low‐rank constraint},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30291}
}
EUVIMED