A framework for rapid, repeatable, and high-fidelity whole-brain multi-pool CEST imaging at 3 T
Magnetic Resonance Imaging · 2026-07 · 130 · 110669
DOI: 10.1016/j.mri.2026.110669 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2026-07. Verfasst von Yupeng Wu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Shanghai Key Laboratory of Magnetic Resonance, Institute of Magnetic Resonance and Molecular Imaging in Medicine, School of Physics, East China Norma…. Hauptthemen laut MEDLINE: Brain, Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Die Arbeit nennt 28 Literaturangaben. Gefördert von: Science and Technology Commission of Shanghai Municipality.
Abstract (Originalsprache)
PURPOSE To develop and validate a framework for rapid, accurate, and repeatable whole-brain, multi-pool chemical exchange saturation transfer (CEST) imaging at 3 T, addressing challenges of long acquisition times and confounding factors. METHODS A single-shot 3D true fast imaging with steady-state precession (True FISP) sequence was optimized for whole-brain multi-pool CEST. Rapid B0, B1, and T1 mapping was performed using a dual-echo modified four-angle method. A feed-forward neural network was developed for rapid B1 correction, trained against the conventional multi-power method. The apparent exchange-dependent relaxation (AREX) metric was used to correct for T1 and magnetization transfer (MT) effects. The framework was validated in phantoms and 50 healthy subjects, including a different-day test-retest repeatability assessment. RESULTS The True FISP sequence yielded high-quality, whole-brain images with minimal artifacts and distortion in a clinically feasible scan time (~9 min). Phantom studies confirmed the effectiveness of B1 correction (coefficient of variation [CV] for the magnetization transfer ratio based on Lorentzian difference (MTRLD) of the MT pool decreased from 22.49% to 4.61%) and AREX-based confounder correction (CV for APT_AREX reduced from 33.6% to 6.9%). The neural network B1 correction showed excellent agreement with the conventional multi-power method in vivo (ICC > 0.95). High different-day test-retest repeatability was demonstrated across 96 brain regions, with the average CV for APT_AREX under 10% for 95 of 96 analyzed regions. CONCLUSION A rapid and robust framework for whole-brain quantitative multi-pool CEST imaging was successfully developed and validated. By integrating an efficient acquisition sequence with a streamlined correction pipeline, this approach overcomes key barriers to clinical translation, enabling reliable metabolic imaging for widespread brain pathologies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Shanghai Key Laboratory of Magnetic Resonance, Institute of Magnetic Resonance and Molecular Imaging in Medicine, School of Physics, East China Normal University, 3663 North Zhongshan Road, Shanghai 200062, China.
- Zhejiang A&F University, No. 666 Wusu Street, Lin'an District, Hangzhou 311300, China.
- MR Collaboration, Siemens (Shenzhen) Magnetic Resonance, Siemens MR Center, Gaoxin C. Ave., 2nd, Hi-Tech Industrial Park, Nanshan District, Shenzhen 518057, China.
- Shanghai Key Laboratory of Magnetic Resonance, Institute of Magnetic Resonance and Molecular Imaging in Medicine, School of Physics, East China Normal University, 3663 North Zhongshan Road, Shanghai 200062, China; Insti…
Förderung
- Science and Technology Commission of Shanghai Municipality
Zitieren
APA
Wu, Y., Fang, S., Wang, S., Fu, C., & Li, J. (2026). A framework for rapid, repeatable, and high-fidelity whole-brain multi-pool CEST imaging at 3 T. Magnetic Resonance Imaging, 130, 110669. https://doi.org/10.1016/j.mri.2026.110669
Vancouver
Wu Y, Fang S, Wang S, Fu C, Li J. A framework for rapid, repeatable, and high-fidelity whole-brain multi-pool CEST imaging at 3 T. Magnetic Resonance Imaging. 2026;130:110669. doi:10.1016/j.mri.2026.110669
BibTeX
@article{Wu2026,
author = {Wu, Yupeng and Fang, Siyuan and Wang, Siyuan and Fu, Caixia and Li, Jianqi},
title = {A framework for rapid, repeatable, and high-fidelity whole-brain multi-pool CEST imaging at 3 T},
journal = {Magnetic Resonance Imaging},
year = {2026},
volume = {130},
pages = {110669},
doi = {10.1016/j.mri.2026.110669}
}
EUVIMED