Generalization of Optimal Control Saturation Pulse Design for Robust and High CEST Contrast
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70150 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Clemens Stilianu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Biomedical Imaging, Graz University of Technology, Graz, Austria. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Austrian Science Fund, Deutsche Forschungsgemeinschaft.
Abstract (Originalsprache)
Purpose
Optimal control (OC) chemical exchange saturation transfer (CEST) pulse design for singular pulses that can be used flexibly and robustly with high saturation at different duty cycles, saturation durations, and magnetic field strengths. Theory and Methods An OC framework was developed to design a single‐pulse shape that can be flexibly applied for arbitrary pulse train parameters and outperform typically used CEST saturation pulse shapes. The pulse design was developed primarily with a continuous‐wave (CW) spectrum as the optimization target, but can be easily adapted to specific scenarios. The generalized OC pulse was evaluated through simulations, a phantom, and in vivo measurements on a 3 T clinical scanner. Performance was assessed in terms of contrast, robustness to field inhomogeneities, and resilience against artifacts such as Rabi oscillations and sidebands, compared to established saturation techniques.
Results
Investigations showed that the generalized OC pulse achieved a contrast matching CW saturation and also functioned well under field inhomogeneities. Low‐pass filtering of the optimized pulse shape effectively suppressed artifacts outside the initial optimization frequency range, enabling generalization across different field strengths. Phantom experiments consistently showed higher contrast than Gaussian, Fermi, and adiabatic spin‐lock (aSL) pulses for various CEST agents covering most clinically relevant regimes. In vivo imaging demonstrated substantially enhanced CEST contrast for both creatine/phosphocreatine in muscle and amide proton transfer (APT) in the brain compared to Gaussian saturation.
Conclusion
The generalized OC pulse provides a robust and flexible alternative to conventional CEST saturation strategies. Its integration into the open‐source Pulseq‐CEST framework supports simple reproducibility and a vendor‐independent implementation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Biomedical Imaging, Graz University of Technology, Graz, Austria.
- Institute of Neuroradiology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), University Hospital Erlangen, Erlangen, Germany.
- High-Field Magnetic Resonance Center, Max-Planck Institute for Biological Cybernetics, Tübingen, Germany.
- BioTechMed Graz, Graz, Austria.
ORCID-Profile: Clemens Stilianu, Markus Huemer, Rudolf Stollberger
Förderung
- Austrian Science Fund
- Deutsche Forschungsgemeinschaft
Zitieren
APA
Stilianu, C., Huemer, M., Zaiss, M., & Stollberger, R. (2026). Generalization of Optimal Control Saturation Pulse Design for Robust and High CEST Contrast. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70150
Vancouver
Stilianu C, Huemer M, Zaiss M, Stollberger R. Generalization of Optimal Control Saturation Pulse Design for Robust and High CEST Contrast. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70150
BibTeX
@article{Stilianu2026,
author = {Stilianu, Clemens and Huemer, Markus and Zaiss, Moritz and Stollberger, Rudolf},
title = {Generalization of Optimal Control Saturation Pulse Design for Robust and High CEST Contrast},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70150}
}
EUVIMED