EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC 4.0

Comparing single-shot EPI and 2D-navigated, multi-shot EPI diffusion tensor imaging acquisitions in the lumbar spinal cord at 3T

Alicia E Cronin, Anna Combes, Lipika Narisetti, Grace Sweeney, Logan Prock, Delaney Houston, Caroline Seehorn, Kurt G Schilling, Ryan K Robison, Seth A Smith, Kristin P O'Grady

Magnetic Resonance Imaging · 2025

DOI: 10.1016/j.mri.2025.110445 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Magnetic Resonance Imaging, 2025. Verfasst von Alicia E Cronin und 10 weiteren Autor:innen. Beteiligte Einrichtung: Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA; Department of Radiology and Radiologica…. Hauptthemen laut MEDLINE: Diffusion Tensor Imaging, Echo-Planar Imaging, Spinal Cord. Die Arbeit nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NCATS NIH HHS, NIBIB NIH HHS, NINDS NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Diffusion tensor imaging (DTI) can provide insights into spinal cord microstructure in health and disease; however, its application has been largely limited to cervical spinal segments using single-shot echo-planar imaging (EPI) diffusion-weighted MRI acquisitions. In this work, we evaluate a multi-shot EPI diffusion-weighted acquisition with reduced field-of-view (FOV) and 2D-navigated motion correction applied in the lumbar spinal cord of healthy volunteers, and compare image quality, geometric distortions, and quantitative DTI indices to those obtained with conventional, single-shot EPI diffusion-weighted MRI in a distinct, age/sex-matched healthy cohort. At 3 Tesla, 25 and 27 healthy participants were imaged using the single-shot and multi-shot EPI readouts with diffusion weighting, respectively, with matching resolution and comparable scan time. Seven participants underwent both diffusion acquisitions and were included in both cohorts. DTI indices were compared between the multi-shot and single-shot cohorts. Image signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) between gray and white matter, geometric distortions, and within-subject bias between the acquisitions were also assessed. The lumbar spinal cord diffusion indices derived from both cohorts were comparable to those in previous studies using single-shot EPI, though within-subject analysis demonstrated a systematic bias between the acquisitions in gray and white matter DTI measures, indicating these acquisitions are not interchangeable within a study. The multi-shot quantitative DTI maps demonstrated a significant reduction in image artifacts (i.e., distortions and blurring) and higher SNR and CNR compared to single-shot images. Overall, the reduced FOV, 2D-navigated, motion-corrected multi-shot acquisition demonstrated improved DTI quality metrics compared to single-shot, supporting its application for the lumbar spinal cord region.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diffusion Tensor ImagingEcho-Planar ImagingSpinal CordHumansMaleFemaleAdultSignal-To-Noise RatioImage Processing, Computer-AssistedMiddle AgedYoung AdultHealthy VolunteersReproducibility of ResultsLumbar VertebraeDiffusion Magnetic Resonance ImagingLumbosacral Region

Stichwörter der Autor:innen

Diffusion tensor imagingLumbar spinal cordMulti-shotSingle-shot

Autor:innen und Institutionen

  • Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA; Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA.
  • Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA; NMR Research Unit, Queen Square Multiple Sclerosis Centre, UCL Queen Square Institute of Neurology, Universit…
  • Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA.
  • Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA; Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA;…

Förderung

  • NCATS NIH HHS
  • NIBIB NIH HHS
  • NINDS NIH HHS
  • National Multiple Sclerosis Society
  • National Institutes of Health
  • Natural Sciences and Engineering Research Council of Canada
  • Vanderbilt University
  • Society for Anthropological Sciences

Zitieren

APA

Cronin, A. E., Combes, A., Narisetti, L., Sweeney, G., Prock, L., Houston, D., Seehorn, C., Schilling, K. G., Robison, R. K., Smith, S. A., & O'Grady, K. P. (2025). Comparing single-shot EPI and 2D-navigated, multi-shot EPI diffusion tensor imaging acquisitions in the lumbar spinal cord at 3T. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2025.110445

Vancouver

Cronin AE, Combes A, Narisetti L, Sweeney G, Prock L, Houston D, et al. Comparing single-shot EPI and 2D-navigated, multi-shot EPI diffusion tensor imaging acquisitions in the lumbar spinal cord at 3T. Magnetic Resonance Imaging. 2025. doi:10.1016/j.mri.2025.110445

BibTeX
@article{Cronin2025,
  author = {Cronin, Alicia E and Combes, Anna and Narisetti, Lipika and Sweeney, Grace and Prock, Logan and Houston, Delaney and Seehorn, Caroline and Schilling, Kurt G and Robison, Ryan K and Smith, Seth A and O'Grady, Kristin P},
  title = {Comparing single-shot EPI and 2D-navigated, multi-shot EPI diffusion tensor imaging acquisitions in the lumbar spinal cord at 3T},
  journal = {Magnetic Resonance Imaging},
  year = {2025},
  doi = {10.1016/j.mri.2025.110445}
}
Kostenlos starten →