Optimized navigator‐based correction of breathing‐induced B 0 field fluctuations in multi‐echo gradient‐echo imaging of the spinal cord
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30475 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Laura Beghini und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics, Norwegian University of Science and Technology, Trondheim, Norway. Hauptthemen laut MEDLINE: Spinal Cord, Image Processing, Computer-Assisted, Echo-Planar Imaging, Magnetic Resonance Imaging. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung.
Abstract (Originalsprache)
Purpose
Multi‐echo gradient‐echo (ME‐GRE) imaging in the spinal cord is susceptible to breathing‐induced B 0 field fluctuations due to the proximity of the lungs, leading to ghosting artifacts. A navigator readout can be used to monitor the fluctuations; however, standard navigator processing often fails in the spinal cord. Here, we introduce navigator processing tailored specifically for spinal cord imaging.
Methods
ME‐GRE data covering all spinal cord regions were acquired in six healthy volunteers during free breathing at 3T. Centerline navigator readouts and respiratory belt recordings were collected during the acquisitions. The navigator processing included a Fast Fourier Transform and subsequent interval selection targeting the spinal cord, as well as SNR‐weighted averaging over samples and coils on the complex data. Furthermore, a phase unwrapping algorithm making use of the belt recordings was developed. Imaging data were corrected by phase demodulation before image reconstruction.
Results
B 0 field fluctuations and ghosting artifacts were largest in the lower cervical and upper lumbosacral cord (˜5 Hz std), close to the edges of the lungs. Image reconstruction based on optimized navigator correction improved visual image quality and quantitative metrics (SNR, contrast‐to‐noise ratio (CNR), ghosting) in all regions of the spinal cord. The improvement was largest in regions with large field fluctuations (group‐averaged increase in SNR/CNR of up to 29%/37% in single‐echo images).
Conclusions
Optimized navigator‐based correction can reduce ghosting artifacts and increase SNR/CNR in anatomical ME‐GRE of the spinal cord. The enhanced image quality and ease of implementation across sites makes the technique attractive for clinical and scientific applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Physics, Norwegian University of Science and Technology, Trondheim, Norway.
- Department of Neuro-Urology, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
- Department of Physics and Astronomy, University of British Columbia, Vancouver, British Columbia, Canada.
- Spinal Cord Injury Center, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
ORCID-Profile: Laura Beghini, Silvan Büeler, Alexander Jaffray, S Johanna Vannesjo
Förderung
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
Zitieren
APA
Beghini, L., Büeler, S., Liechti, M. D., Jaffray, A., David, G., & Vannesjo, S. J. (2025). Optimized navigator‐based correction of breathing‐induced B 0 field fluctuations in multi‐echo gradient‐echo imaging of the spinal cord. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30475
Vancouver
Beghini L, Büeler S, Liechti MD, Jaffray A, David G, Vannesjo SJ. Optimized navigator‐based correction of breathing‐induced B 0 field fluctuations in multi‐echo gradient‐echo imaging of the spinal cord. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30475
BibTeX
@article{Beghini2025,
author = {Beghini, Laura and Büeler, Silvan and Liechti, Martina D and Jaffray, Alexander and David, Gergely and Vannesjo, S Johanna},
title = {Optimized navigator‐based correction of breathing‐induced B 0 field fluctuations in multi‐echo gradient‐echo imaging of the spinal cord},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30475}
}
EUVIMED