Influence of scanning plane on Human Spinal Cord functional Magnetic Resonance echo planar imaging
PLOS One · 2025
DOI: 10.1371/journal.pone.0320188 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS One, 2025. Verfasst von Marta Moraschi und 13 weiteren Autor:innen. Beteiligte Einrichtung: Fondazione Santa Lucia IRCCS, Rome, Italy. Hauptthemen laut MEDLINE: Spinal Cord, Echo-Planar Imaging, Magnetic Resonance Imaging. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union - Next Generation EU - NRRP M6C2.
Abstract (Originalsprache)
Background
Functional Magnetic Resonance Imaging (fMRI) is based on the Blood Oxygenation Level Dependent contrast and has been exploited for the indirect study of the neuronal activity within both the brain and the spinal cord. However, the interpretation of spinal cord fMRI (scfMRI) is still controversial and its adoption is rather restricted because of technical limitations. Overcoming these limitations would have a beneficial effect for the assessment and follow-up of spinal injuries and neurodegenerative diseases.
Purpose
This study was aimed at systematically verifying whether sagittal scanning in scfMRI using EPI readout is a viable alternative to the more common axial scanning, and at optimizing a pipeline for EPI-based scfMRI data analysis, based on Spinal Cord Toolbox (SCT).
Methods
Forty-five healthy subjects underwent MRI acquisition in a Philips Achieva 3T MRI scanner. T 2 *-weighted fMRI data were acquired using a GE-EPI sequence along sagittal and axial planes during an isometric motor task. Differences on benchmarks were assessed via paired two-sample t-test at p < 0.05.
Results
We investigated the impact of the acquisition strategy by means of various metrics such as Temporal Signal to Noise Ratio (tSNR) , Dice Coefficient to assess geometric distortions, Reproducibility and BOLD signal sensitivity to the stimulus . tSNR was higher in axial than in sagittal scans, as well as reproducibility within the whole cord mask (t = 7.4, p < 0.01) and within the GM mask (t = 4.2, p < 0.01). The other benchmarks, associated with distortion and functional response, showed no difference between images obtained along the axial and sagittal planes.
Conclusions
Quantitative metrics of data quality suggest that axial scanning would be the optimal choice. We conclude that axial acquisition is advantageous specially to mitigate the effects of physiological noise and to minimize inter-subject variance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Fondazione Santa Lucia IRCCS, Rome, Italy.
- Operative Research Unit of Radiation Oncology, Campus Bio-Medico University of Rome, Rome, Italy.
- Human Neuroscience Department, Sapienza University of Rome, Rome, Italy.
- UniCamillus-International Medical University in Rome, Rome, Italy.
- MARBILab-Museo Storico della Fisica e Centro Studi e Ricerche Enrico Fermi, Rome, Italy.
- NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montreal, Montreal, Québec, Canada.
ORCID-Profile: Silvia Tommasin
Förderung
- European Union - Next Generation EU - NRRP M6C2
Zitieren
APA
Moraschi, M., Tommasin, S., Maugeri, L., DiNuzzo, M., Cohen-Adad, J., Masullo, M., Mangini, F., Giovannelli, L., Mascali, D., Gili, T., Pisani, V., Nocentini, U., Giove, F., & Fratini, M. (2025). Influence of scanning plane on Human Spinal Cord functional Magnetic Resonance echo planar imaging. PLOS One. https://doi.org/10.1371/journal.pone.0320188
Vancouver
Moraschi M, Tommasin S, Maugeri L, DiNuzzo M, Cohen-Adad J, Masullo M, et al. Influence of scanning plane on Human Spinal Cord functional Magnetic Resonance echo planar imaging. PLOS One. 2025. doi:10.1371/journal.pone.0320188
BibTeX
@article{Moraschi2025,
author = {Moraschi, Marta and Tommasin, Silvia and Maugeri, Laura and DiNuzzo, Mauro and Cohen-Adad, Julien and Masullo, Marco and Mangini, Fabio and Giovannelli, Lorenzo and Mascali, Daniele and Gili, Tommaso and Pisani, Valerio and Nocentini, Ugo and Giove, Federico and Fratini, Michela},
title = {Influence of scanning plane on Human Spinal Cord functional Magnetic Resonance echo planar imaging},
journal = {PLOS One},
year = {2025},
doi = {10.1371/journal.pone.0320188}
}
EUVIMED