Three‐Dimensional Single‐Shot CEST Imaging at 3T Based on True FISP Readout

Yupeng Wu iD, Qifan Pang, Zhichao Wang, Gaiying Li, Caixia Fu, Mengqiu Cao, Xingrui Wang, Dongmei Jiang, Dejun She, Yang Song, Yu Zhao, Jianqi Li iD

NMR in Biomedicine · 2025-09 · 38 (9)

DOI: 10.1002/nbm.70109 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, online erschienen am 26.07.2025. Verfasst von Yupeng Wu und 11 weiteren Autor:innen. Beteiligte Einrichtung: Shanghai Key Laboratory of Magnetic Resonance, School of Physics and Electronic Science, East China Normal University, Shanghai, China. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Magnetic Resonance Imaging. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 63 Literaturangaben. Gefördert von: STI 2030-Major Projects, Microscale Magnetic Resonance Platform of East China Normal University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To simultaneously fit multiple‐pool effects, spectrally selective 3D chemical exchange saturation transfer (CEST) imaging typically requires single‐shot readouts to save time. However, to date, fast low angle shot (FLASH) and echo planar imaging (EPI) have been the primary pulse sequences used for this purpose. They suffer from low signal‐to‐noise ratio (SNR) or image distortion related to B0 field inhomogeneity. In this work, we developed a 3D single‐shot CEST sequence using true fast imaging with steady‐state precession (True FISP) readout, also known as balanced steady state free precession (bSSFP), and optimized the scanning parameters through simulations. The performance of the CEST sequence was validated using an egg white phantom, 10 healthy volunteers, and two patients with brain tumors on a 3T human scanner. Subsequently, the proposed CEST sequence using True FISP was compared with the commonly used FLASH‐based CEST sequence, focusing on SNR and image contrast, while maintaining identical pre‐saturation modes, repetition time, echo time, and scan time. In the simulation experiments, the maximum CEST signal obtained from the True FISP was significantly greater than that obtained from the FLASH sequence. In the egg white phantom, the SNRs of amide proton transfer‐weighted (APTw) and nuclear Overhauser enhancement (NOE) effect images obtained from the True FISP were 68.3% and 57.0% higher than those obtained from the FLASH sequence, respectively. In healthy volunteers, saturated images collected with the True FISP sequence at 3.5 ppm showed an approximately 84% increase in mean temporal SNR compared to those collected with the FLASH sequence. Compared to the FLASH sequence, the CEST images obtained from the True FISP sequence could display more detailed brain tissue structures of both normal individuals and patients with brain tumors. Therefore, due to the high SNR inherent in the sequence, True FISP has the potential to be used for fast and high‐quality 3D image readout of CEST contrasts in clinical applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalMagnetic Resonance ImagingHumansPhantoms, ImagingSignal-To-Noise RatioAdultFemaleMaleBrain NeoplasmsEcho-Planar Imaging

Stichwörter der Autor:innen

CESTbalanced steady state free precession (bSSFP)fast imagingthree‐dimensional (3D)true fast imaging with steady‐state precession (True FISP)

Autor:innen und Institutionen

  • Shanghai Key Laboratory of Magnetic Resonance, School of Physics and Electronic Science, East China Normal University, Shanghai, China.
  • Zhejiang Lab, Zhejiang, Hangzhou, China.
  • MR Collaboration, Siemens (Shenzhen) Magnetic Resonance, Shenzhen, China.
  • Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
  • Department of Radiology, First Affiliated Hospital of Fujian Medical University, Fuzhou, China.
  • MR Scientific Marketing, Siemens Healthineers, Shanghai, China.

ORCID-Profile: Yupeng Wu, Jianqi Li

Förderung

  • STI 2030-Major Projects
  • Microscale Magnetic Resonance Platform of East China Normal University

Zitieren

APA

Wu, Y., Pang, Q., Wang, Z., Li, G., Fu, C., Cao, M., Wang, X., Jiang, D., She, D., Song, Y., Zhao, Y., & Li, J. (2025). Three‐Dimensional Single‐Shot CEST Imaging at 3T Based on True FISP Readout. NMR in Biomedicine, 38(9). https://doi.org/10.1002/nbm.70109

Vancouver

Wu Y, Pang Q, Wang Z, Li G, Fu C, Cao M, et al. Three‐Dimensional Single‐Shot CEST Imaging at 3T Based on True FISP Readout. NMR in Biomedicine. 2025;38(9). doi:10.1002/nbm.70109

BibTeX
@article{Wu2025,
  author = {Wu, Yupeng and Pang, Qifan and Wang, Zhichao and Li, Gaiying and Fu, Caixia and Cao, Mengqiu and Wang, Xingrui and Jiang, Dongmei and She, Dejun and Song, Yang and Zhao, Yu and Li, Jianqi},
  title = {Three‐Dimensional Single‐Shot CEST Imaging at 3T Based on True FISP Readout},
  journal = {NMR in Biomedicine},
  year = {2025},
  volume = {38},
  number = {9},
  doi = {10.1002/nbm.70109}
}
Kostenlos starten →