Single‐shot diffusion trace spectroscopic imaging using radial echo planar trajectories
Magnetic Resonance in Medicine · 2024
DOI: 10.1002/mrm.30125 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Andres Saucedo und 1 weiteren Autor:innen. Beteiligte Einrichtung: Radiological Sciences, University of California at Los Angeles, Los Angeles, California, USA. Hauptthemen laut MEDLINE: Phantoms, Imaging, Echo-Planar Imaging, Diffusion Magnetic Resonance Imaging, Brain. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 68 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIMH NIH HHS, National Institute of Mental Health.
Abstract (Originalsprache)
Purpose
Demonstrate the feasibility and evaluate the performance of single‐shot diffusion trace‐weighted radial echo planar spectroscopic imaging (Trace DW‐REPSI) for quantifying the trace ADC in phantom and in vivo using a 3T clinical scanner. Theory and Methods Trace DW‐REPSI datasets were acquired in 10 phantom and 10 healthy volunteers, with a maximum b ‐value of 1601 s/mm 2 and diffusion time of 10.75 ms. The self‐navigation properties of radial acquisitions were used for corrections of shot‐to‐shot phase and frequency shift fluctuations of the raw data. In vivo trace ADCs of total NAA (tNAA), total creatine (tCr), and total choline (tCho) extrapolated to pure gray and white matter fractions were compared, as well as trace ADCs estimated in voxels within white or gray matter‐dominant regions.
Results
Trace ADCs in phantom show excellent agreement with reported values, and in vivo ADCs agree well with the expected differences between gray and white matter. For tNAA, tCr, and tCho, the trace ADCs extrapolated to pure gray and white matter ranged from 0.18–0.27 and 0.26–0.38 μm 2 /ms, respectively. In sets of gray and white matter‐dominant voxels, the values ranged from 0.21 to 0.27 and 0.24 to 0.31 μm 2 /ms, respectively. The overestimated trace ADCs from this sequence can be attributed to the short diffusion time.
Conclusion
This study presents the first demonstration of the single‐shot diffusion trace‐weighted spectroscopic imaging sequence using radial echo planar trajectories. The Trace DW‐REPSI sequence could provide an estimate of the trace ADC in a much shorter scan time compared to conventional approaches that require three separate measurements.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Radiological Sciences, University of California at Los Angeles, Los Angeles, California, USA.
- Physics and Biology in Medicine Interdepartmental Graduate Program, David Geffen School of Medicine, University of California at Los Angeles, Los Angeles, California, USA.
- Psychiatry, University of California at Los Angeles, Los Angeles, California, USA.
ORCID-Profile: Andres Saucedo, M Albert Thomas
Förderung
- NIMH NIH HHS
- National Institute of Mental Health
Zitieren
APA
Saucedo, A., & Thomas, M. A. (2024). Single‐shot diffusion trace spectroscopic imaging using radial echo planar trajectories. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30125
Vancouver
Saucedo A, Thomas MA. Single‐shot diffusion trace spectroscopic imaging using radial echo planar trajectories. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30125
BibTeX
@article{Saucedo2024,
author = {Saucedo, Andres and Thomas, M Albert},
title = {Single‐shot diffusion trace spectroscopic imaging using radial echo planar trajectories},
journal = {Magnetic Resonance in Medicine},
year = {2024},
doi = {10.1002/mrm.30125}
}
EUVIMED