The dosimetric impact to bladder utilizing the Varian Edge linear accelerator for prostate stereotactic body radiation therapy
Medical Dosimetry · 2026 · 51 (4) · 486-492
DOI: 10.1016/j.meddos.2026.05.005 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Dosimetry, 2026. Verfasst von Cassandra Sonnicksen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Medical Dosimetry Program, University of Wisconsin, La Crosse, WI, 54601, USA. Hauptthemen laut MEDLINE: Prostatic Neoplasms, Radiosurgery, Urinary Bladder, Particle Accelerators. Die Arbeit nennt 7 Literaturangaben.
Abstract (Originalsprache)
Stereotactic body radiation therapy (SBRT) is increasingly utilized for low and intermediate grade prostate cancer, offering advantages in reducing toxicities to critical structures and improving dose conformity. However, minimizing bladder toxicity remains challenging due to the organ's close proximity to the target. The Varian Edge linear accelerator utilizes high-resolution 2.5 mm multileaf collimators, enabling enhanced beam shaping and potentially improving organ at risk sparing. Limited data exist on the dosimetric impact of prostate SBRT planned with the Varian Edge linear accelerator. The goal of this study was to evaluate bladder toxicity in prostate SBRT planning by comparing treatment plans generated for delivery on the Varian TrueBeam and Varian Edge linear accelerators. It was hypothesized that plans utilizing the Varian Edge linear accelerator would result in a volume of the bladder receiving 34 Gy (V34 Gy) ≤ 5 cubic centimeters (cc), volume of the bladder receiving 37 Gy ≤ 5 cc, dose to the most exposed 1 cc (D1 cc) of the bladder ≤ 38.06 Gy, and maximum dose to 0.03 cc (D0.03 cc) of the bladder ≤ 38.06 Gy. Ten patients were retrospectively analyzed, and the results demonstrated significant reductions in the V34 Gy and V37 Gy of the bladder for the plans designed for delivery on the Varian Edge linear accelerator. There were no meaningful differences observed for the D1 cc and D0.03 cc. While the Varian Edge linear accelerator provides measurable dosimetric advantages in reducing intermediate dosing to the bladder, larger prospective studies with long-term follow-up are needed to determine whether these reductions translate into improved quality of life and reduced urinary toxicity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Medical Dosimetry Program, University of Wisconsin, La Crosse, WI, 54601, USA.
- Medical Dosimetry Program, University of Wisconsin, La Crosse, WI, 54601, USA. Electronic address: nlenards@uwlax.edu.
Zitieren
APA
Sonnicksen, C., Haugland, L., Slater, K., Lenards, N., Hunzeker, A., & McKane, B. (2026). The dosimetric impact to bladder utilizing the Varian Edge linear accelerator for prostate stereotactic body radiation therapy. Medical Dosimetry, 51(4), 486-492. https://doi.org/10.1016/j.meddos.2026.05.005
Vancouver
Sonnicksen C, Haugland L, Slater K, Lenards N, Hunzeker A, McKane B. The dosimetric impact to bladder utilizing the Varian Edge linear accelerator for prostate stereotactic body radiation therapy. Medical Dosimetry. 2026;51(4):486-492. doi:10.1016/j.meddos.2026.05.005
BibTeX
@article{Sonnicksen2026,
author = {Sonnicksen, Cassandra and Haugland, Leia and Slater, Kelsey and Lenards, Nishele and Hunzeker, Ashley and McKane, Brittni},
title = {The dosimetric impact to bladder utilizing the Varian Edge linear accelerator for prostate stereotactic body radiation therapy},
journal = {Medical Dosimetry},
year = {2026},
volume = {51},
number = {4},
pages = {486--492},
doi = {10.1016/j.meddos.2026.05.005}
}
EUVIMED