Effect of Anterior vs Posterior Dispersive Patch Placement on Radiofrequency Ablation Lesion Size in Swine
JACC: Clinical Electrophysiology · 2025
DOI: 10.1016/j.jacep.2025.04.009 ↗Kurz gefasst
Fachartikel in der Zeitschrift JACC: Clinical Electrophysiology, 2025. Verfasst von Ramkumar V Venkateswaran und 4 weiteren Autor:innen. Beteiligte Einrichtung: Cardiac Electrophysiology and Arrhythmia Service, University of California-San Francisco, San Francisco, California, USA. Hauptthemen laut MEDLINE: Catheter Ablation, Heart Ventricles, Tachycardia, Ventricular, Radiofrequency Ablation. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 15 Literaturangaben. Gefördert von: University of California, San Francisco, Abbott Vascular.
Abstract (Originalsprache)
BACKGROUND: Ablation of ventricular tachycardia using radiofrequency (RF) energy can be challenging for deep circuits. Standard RF ablation is monopolar, with energy delivered between the catheter and a dispersive patch (DP). Aligning the DP with the direction of RF application may shift the RF field to create deeper lesions. OBJECTIVES: The authors sought to compare left ventricular lesion size with concordant (patch oriented in the direction of ablation) versus discordant DP placement in swine. METHODS: An irrigated, contact force sensing RF catheter was used to apply lesions to the anterior and posterior left ventricles in swine. Two DPs were attached, and the ground was randomly chosen so that one-half of the lesions were concordant (eg, anterior RF/anterior DP) and one-half were discordant (eg, anterior RF/posterior DP). Ablation parameters otherwise remained constant. RESULTS: A total of 77 lesions (38 concordant, 39 discordant) in 10 swine were analyzed. Contact force (18.0 ± 3.2 g vs 17.6 ± 3.5 g; P = 0.606) and baseline impedance (111.3 ± 7.5 Ω vs 110.9 ± 7.3 Ω; P = 0.782) were similar between groups. Lesions with concordant compared with discordant DP had greater lesion depth (7.4 ± 1.8 vs 6.1 ± 1.6 mm; P = 0.001) and area (72.5 ± 22.2 mm2 vs 59.6 ± 17.5 mm2; P = 0.006). CONCLUSIONS: Placing the DP on the body surface concordant with the direction of RF ablation results in ∼20% increase in lesion depth. This simple modification can be used to enhance RF lesion size.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cardiac Electrophysiology and Arrhythmia Service, University of California-San Francisco, San Francisco, California, USA.
- Cardiac Electrophysiology and Arrhythmia Service, University of California-San Francisco, San Francisco, California, USA. Electronic address: Edward.Gerstenfeld@uvcsf.edu.
Förderung
- University of California, San Francisco
- Abbott Vascular
Zitieren
APA
Venkateswaran, R. V., Kataoka, S., Kwon, C. H., Lee, S. H., & Gerstenfeld, E. P. (2025). Effect of Anterior vs Posterior Dispersive Patch Placement on Radiofrequency Ablation Lesion Size in Swine. JACC: Clinical Electrophysiology. https://doi.org/10.1016/j.jacep.2025.04.009
Vancouver
Venkateswaran RV, Kataoka S, Kwon CH, Lee SH, Gerstenfeld EP. Effect of Anterior vs Posterior Dispersive Patch Placement on Radiofrequency Ablation Lesion Size in Swine. JACC: Clinical Electrophysiology. 2025. doi:10.1016/j.jacep.2025.04.009
BibTeX
@article{Venkateswaran2025,
author = {Venkateswaran, Ramkumar V and Kataoka, Shohei and Kwon, Chang Hee and Lee, Sung Ho and Gerstenfeld, Edward P},
title = {Effect of Anterior vs Posterior Dispersive Patch Placement on Radiofrequency Ablation Lesion Size in Swine},
journal = {JACC: Clinical Electrophysiology},
year = {2025},
doi = {10.1016/j.jacep.2025.04.009}
}
EUVIMED