MRI Accurately Visualizes RF Ablation Delivery Targeted to MRI-Defined Arrhythmia Substrates in the Left Ventricle
IEEE Transactions on Biomedical Engineering · 2024
DOI: 10.1109/tbme.2024.3392333 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Engineering, 2024. Verfasst von Philippa R P Krahn und 7 weiteren Autor:innen. Hauptthemen laut MEDLINE: Heart Ventricles, Magnetic Resonance Imaging. Die Arbeit nennt 38 Literaturangaben. Gefördert von: Federal Development Agency of Canada, Canadian Institutes of Health Research, GE Healthcare.
Abstract (Originalsprache)
OBJECTIVE: Investigate the capacity of MRI to evaluate efficacy of radiofrequency (RF) ablations delivered to MRI-defined arrhythmogenic substrates. METHODS: Baseline MRI was performed at 3 T including 3D LGE in a swine model of chronic myocardial infarct (N = 8). MRI-derived maps of scar and heterogeneous tissue channels (HTCs) were generated using ADAS 3D. Animals underwent electroanatomic mapping and ablation of the left ventricle in CARTO3, guided by MRI-derived scar maps. Post-ablation MRI (in vivo at 3 T in 5/8 animals; ex vivo at 1.5 T in 3/8) included 3D native T1-weighted IR-SPGR (TI = 700-800 ms) to visualize RF lesions. T1-derived RF lesions were compared against excised tissue. The locations of T1-derived RF lesions were compared against CARTO ablation tags, and segment-wise sensitivity and specificity of lesion detection were calculated within the AHA 17-segment model. RESULTS: RF lesions were clearly visualized in HTCs, scar, and myocardium. Ablation patterns delivered in CARTO matched T1-derived RF lesion patterns with high sensitivity (88.9%) and specificity (94.7%), and were closely matched in registered MR-EP data sets, with a displacement of 5.4 ±3.8 mm (N = 152 ablation tags). CONCLUSION: Integrating MRI into ablative procedures for RF lesion assessment is feasible. Patterns of RF lesions created using a standard 3D EAM system are accurately reflected by MRI visualization in healthy myocardium, scar, and HTCs comprising the MRI-defined arrhythmia substrate. SIGNIFICANCE: MRI visualization of RF lesions can provide near-immediate ( 24 h) assessment of ablation, potentially indicating whether critical MRI-defined ventricular tachycardia substrates have been adequately ablated.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Förderung
- Federal Development Agency of Canada
- Canadian Institutes of Health Research
- GE Healthcare
- Ontario Graduate Scholarship
Zitieren
APA
Krahn, P. R. P., Escartin, T., Singh, S. M., Barry, J., Larsen, M., Guo, F., Pop, M., & Wright, G. A. (2024). MRI Accurately Visualizes RF Ablation Delivery Targeted to MRI-Defined Arrhythmia Substrates in the Left Ventricle. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2024.3392333
Vancouver
Krahn PRP, Escartin T, Singh SM, Barry J, Larsen M, Guo F, et al. MRI Accurately Visualizes RF Ablation Delivery Targeted to MRI-Defined Arrhythmia Substrates in the Left Ventricle. IEEE Transactions on Biomedical Engineering. 2024. doi:10.1109/tbme.2024.3392333
BibTeX
@article{Krahn2024,
author = {Krahn, Philippa R P and Escartin, Terenz and Singh, Sheldon M and Barry, Jennifer and Larsen, Melissa and Guo, Fumin and Pop, Mihaela and Wright, Graham A},
title = {MRI Accurately Visualizes RF Ablation Delivery Targeted to MRI-Defined Arrhythmia Substrates in the Left Ventricle},
journal = {IEEE Transactions on Biomedical Engineering},
year = {2024},
doi = {10.1109/tbme.2024.3392333}
}
EUVIMED