EUVIMEDEUVIMED entdecken
Crossref

Feasibility and safety of pulsed field ablation at the ventricular outflow tract using focal point catheter

Lihui Zheng, Pakezhati Maimaitijiang, Aiyue Chen, Zihao Lai, Yan Yao

Heart Rhythm · 2025

DOI: 10.1016/j.hrthm.2024.10.059 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Heart Rhythm, 2025. Verfasst von Lihui Zheng und 4 weiteren Autor:innen. Beteiligte Einrichtung: Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College,…. Hauptthemen laut MEDLINE: Catheter Ablation, Heart Ventricles, Tachycardia, Ventricular. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 24 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Chinese Academy of Medical Sciences Innovation Fund for Medical Sciences, Chinese Academy of Medical Sciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Ventricular arrhythmias commonly originate from the ventricular outflow tract. It remains unexplored whether pulsed field ablation (PFA) can create durable lesions safely at the ventricular outflow tract. OBJECTIVE: This study aimed to evaluate the feasibility and safety of a novel PFA catheter to deliver focal ablation to the ventricular outflow tract, especially pulmonary and aortic sinus cusps (PSCs and ASCs). METHODS: Twelve swine were divided into 3 groups: 24-hour, 2-week, and 4-week post-ablation. PFA was delivered to predefined sites of PSCs and ASCs with a focal point catheter, positioned by a mapping system, fluoroscopy, and intracardiac echocardiography. Electrophysiologic assessment, coronary angiography, transesophageal echocardiography, and gross and histologic examination were performed to evaluate the impact of PFA delivery on cardiac structure and function. RESULTS: All subjects survived, and no adverse events were observed. There was a significant decrease in voltage amplitude and increase in pacing thresholds at PSCs and ASCs. There were no significant differences in AH or HV intervals between pre-ablation and post-ablation (AH, P = .70; HV, P = .90). After PFA delivery to ASCs, coronary arteries were fully perfused in each heart, without ST-segment elevation observed. No severe valvular dysfunction was observed on intracardiac echocardiography and transesophageal echocardiography. Gross and histologic examination confirmed the creation of well-demarcated lesions at the targeted sites without damage to adjacent structures. CONCLUSION: PFA delivered by the focal point catheter could create durable lesions at PSCs and ASCs without damage to coronary arteries, atrioventricular block, or valvular dysfunction, indicative of the feasibility and safety of this novel PFA catheter at the ventricular outflow tract.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Catheter AblationHeart VentriclesTachycardia, VentricularAnimalsSwineFeasibility StudiesEchocardiography, TransesophagealDisease Models, AnimalCoronary AngiographyElectrophysiologic Techniques, Cardiac

Stichwörter der Autor:innen

Aortic sinus cuspFeasibilityPulmonary sinus cuspPulsed field ablationSafetyVentricular outflow tract

Autor:innen und Institutionen

  • Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China. Electronic address: zhenglihui@263.net.
  • Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China. Electronic address: ianyao@263.net.cn.

Förderung

  • National Natural Science Foundation of China
  • Chinese Academy of Medical Sciences Innovation Fund for Medical Sciences
  • Chinese Academy of Medical Sciences

Zitieren

APA

Zheng, L., Maimaitijiang, P., Chen, A., Lai, Z., & Yao, Y. (2025). Feasibility and safety of pulsed field ablation at the ventricular outflow tract using focal point catheter. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2024.10.059

Vancouver

Zheng L, Maimaitijiang P, Chen A, Lai Z, Yao Y. Feasibility and safety of pulsed field ablation at the ventricular outflow tract using focal point catheter. Heart Rhythm. 2025. doi:10.1016/j.hrthm.2024.10.059

BibTeX
@article{Zheng2025,
  author = {Zheng, Lihui and Maimaitijiang, Pakezhati and Chen, Aiyue and Lai, Zihao and Yao, Yan},
  title = {Feasibility and safety of pulsed field ablation at the ventricular outflow tract using focal point catheter},
  journal = {Heart Rhythm},
  year = {2025},
  doi = {10.1016/j.hrthm.2024.10.059}
}
Kostenlos starten →