EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Optimizing IVIM measurement on magnetic resonance linear accelerator using multi-b-value acquisition and physics-informed neural network

Xinxiang Zhou, Na Huang, Zengyi Fang, Jie Tang, Tingting Zhang, Yulu Zhao, Lucia Clara Orlandini, Pei Wang, Jingyi Lang, Meihua Chen

Physica Medica · 2026

DOI: 10.1016/j.ejmp.2026.107205 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physica Medica, 2026. Verfasst von Xinxiang Zhou und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Sichuan Clinical Research Center for Cancer, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of …. Hauptthemen laut MEDLINE: Particle Accelerators, Image Processing, Computer-Assisted, Diffusion Magnetic Resonance Imaging, Neural Networks, Computer. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Science and Technology Department of Sichuan Province, Natural Science Foundation of Sichuan Province, Fundamental Research Funds for the Central Universities.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Accurate quantification of intravoxel incoherent motion (IVIM) parameters on the magnetic resonance linear accelerator (MR-Linac) is challenging due to low signal-to-noise ratio and time constraints. PURPOSE: This study aimed to evaluate the impact of b-value acquisition strategies and estimation algorithms on IVIM parameter measurement to guide reliable IVIM quantification on the MR-Linac. METHODS: A digital phantom with high number of signals averaged (high-NSA) and multi-b-value signals was constructed to evaluate estimation accuracy using root mean square error (RMSE). Ten healthy volunteers underwent four repeated diffusion-weighted imaging (DWI) scans, consisting of two high-NSA DWIs and two multi-b-value DWIs to assess repeatability via the within-subject coefficient of variation (wCV). IVIM parameters from high-NSA DWI were estimated using Segment fitting, while multi-b-value DWI data were processed using least squares (LS), Bayesian estimation, and physics-informed neural network (PINN). RESULTS: All IVIM parameters from multi-b-value DWI exhibited lower wCVs than those from high-NSA DWI, except for the LS-derived diffusion coefficient (D). Multi-b-value DWI combined with PINN achieved rapid and highly repeatable estimation. In the digital phantom, high-NSA DWI with Segment fitting yielded the highest RMSE for the pseudo-diffusion coefficient (D∗). LS and Bayesian methods resulted in higher D RMSEs and required longer fitting times. In contrast, multi-b-value DWI + PINN achieved the lowest RMSEs across all parameters with minimal computational cost. CONCLUSION: The combination of multi-b-value acquisition and PINN provided a robust and accurate framework for IVIM parameter estimation on the MR-Linac and showed potential for integration into MR-Linac quantitative imaging workflows.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Particle AcceleratorsImage Processing, Computer-AssistedDiffusion Magnetic Resonance ImagingNeural Networks, ComputerHumansPhantoms, ImagingMovementAlgorithms

Stichwörter der Autor:innen

Diffusion-weighted imagingIntravoxel incoherent motionMR-LinacParameter estimation

Autor:innen und Institutionen

  • Department of Radiation Oncology, Sichuan Clinical Research Center for Cancer, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, No…
  • Department of Radiation Oncology, Precision Radiation in Oncology Key Laboratory of Sichuan Province, Sichuan Clinical Research Center for Cancer, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, University o…
  • Department of Oncology, School of Clinical Medicine, Southwest Medical University, Luzhou, 646000, Sichuan, China.
  • School of Medical and Life Sciences, Chengdu University of Traditional Chinese Medicine, Chengdu, 611137, Sichuan, China.

Förderung

  • Science and Technology Department of Sichuan Province
  • Natural Science Foundation of Sichuan Province
  • Fundamental Research Funds for the Central Universities

Zitieren

APA

Zhou, X., Huang, N., Fang, Z., Tang, J., Zhang, T., Zhao, Y., Orlandini, L. C., Wang, P., Lang, J., & Chen, M. (2026). Optimizing IVIM measurement on magnetic resonance linear accelerator using multi-b-value acquisition and physics-informed neural network. Physica Medica. https://doi.org/10.1016/j.ejmp.2026.107205

Vancouver

Zhou X, Huang N, Fang Z, Tang J, Zhang T, Zhao Y, et al. Optimizing IVIM measurement on magnetic resonance linear accelerator using multi-b-value acquisition and physics-informed neural network. Physica Medica. 2026. doi:10.1016/j.ejmp.2026.107205

BibTeX
@article{Zhou2026,
  author = {Zhou, Xinxiang and Huang, Na and Fang, Zengyi and Tang, Jie and Zhang, Tingting and Zhao, Yulu and Orlandini, Lucia Clara and Wang, Pei and Lang, Jingyi and Chen, Meihua},
  title = {Optimizing IVIM measurement on magnetic resonance linear accelerator using multi-b-value acquisition and physics-informed neural network},
  journal = {Physica Medica},
  year = {2026},
  doi = {10.1016/j.ejmp.2026.107205}
}
Kostenlos starten →