Dosimetric and temporal beam characterization of individual pulses in FLASH radiotherapy using Timepix3 pixelated detector placed out-of-field

Cristina Oancea, Katerina Sykorova, Jan Jakubek, Jiri Pivec, Felix Riemer, Steven Worm, Alexandra Bourgouin

Physica Medica · 2025

DOI: 10.1016/j.ejmp.2024.104872 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physica Medica, 2025. Verfasst von Cristina Oancea und 6 weiteren Autor:innen. Beteiligte Einrichtung: ADVACAM, U Pergamenky 12, 170 00 Prague 7, Czech Republic. Electronic address: cristina.oancea@advacam.cz. Hauptthemen laut MEDLINE: Radiometry, Particle Accelerators, Radiotherapy Dosage. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 49 Literaturangaben. Gefördert von: European Metrology Programme for Innovation and Research, Horizon 2020 Framework Programme, EURAMET EMPIR.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: FLASH radiotherapy necessitates the development of advanced Quality Assurance methods and detectors for accurate monitoring of the radiation field. This study introduces enhanced time-resolution detection systems and methods used to measure the delivered number of pulses, investigate temporal structure of individual pulses and dose-per-pulse (DPP) based on secondary radiation particles produced in the experimental room. METHODS: A 20 MeV electron beam generated from a linear accelerator (LINAC) was delivered to a water phantom. Ultra-high dose-per-pulse electron beams were used with a dose-per-pulse ranging from ̴ 1 Gy to over 7 Gy. The pulse lengths ranged from 1.18 µs to 2.88 µs at a pulse rate frequency of 5 Hz. A semiconductor pixel detector Timepix3 was used to track single secondary particles. Measurements were performed in the air, while the detector was positioned out-of-field at a lateral distance of 200 cm parallel with the LINAC exit window. The dose deposited was measured along with the pulse length and the nanostructure of the pulse. RESULTS: The time of arrival (ToA) of single particles was measured with a resolution of 1.56 ns, while the deposited energy was measured with a resolution of several keV based on the Time over Threshold (ToT) value. The pulse count measured by the Timepix3 detector corresponded with the delivered values, which were measured using an in-flange integrating current transformer (ICT). A linear response (R2 = 0.999) was established between the delivered beam current and the measured dose at the detector position (orders of nGy). The difference between the average measured and delivered pulse length was ∼0.003(30) μs. CONCLUSION: This simple non-invasive method exhibits no limitations on the delivered DPP within the range used during this investigation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadiometryParticle AcceleratorsRadiotherapy DosageTime FactorsPhantoms, ImagingRadiotherapy

Stichwörter der Autor:innen

FLASH electronFLASH electron radiotherapyFast neutronsOut-of-field doseParticle fluxSingle pulseTime measurementTimepix3 pixel detector

Autor:innen und Institutionen

  • ADVACAM, U Pergamenky 12, 170 00 Prague 7, Czech Republic. Electronic address: cristina.oancea@advacam.cz.
  • ADVACAM, U Pergamenky 12, 170 00 Prague 7, Czech Republic.
  • Deutsches Elektronen-Synchrotron DESY, Platanenallee 6, 15738 Zeuthen, Germany.
  • Dosimetry for Radiation Therapy and Diagnostic Radiology, Physikalisch-Technische Bundesanstalt (PTB), Braunschweig 38116, Germany; Metrology Research Center, National Research Council of Canada, 1200 Montreal Road, Ott…

Förderung

  • European Metrology Programme for Innovation and Research
  • Horizon 2020 Framework Programme
  • EURAMET EMPIR

Zitieren

APA

Oancea, C., Sykorova, K., Jakubek, J., Pivec, J., Riemer, F., Worm, S., & Bourgouin, A. (2025). Dosimetric and temporal beam characterization of individual pulses in FLASH radiotherapy using Timepix3 pixelated detector placed out-of-field. Physica Medica. https://doi.org/10.1016/j.ejmp.2024.104872

Vancouver

Oancea C, Sykorova K, Jakubek J, Pivec J, Riemer F, Worm S, et al. Dosimetric and temporal beam characterization of individual pulses in FLASH radiotherapy using Timepix3 pixelated detector placed out-of-field. Physica Medica. 2025. doi:10.1016/j.ejmp.2024.104872

BibTeX
@article{Oancea2025,
  author = {Oancea, Cristina and Sykorova, Katerina and Jakubek, Jan and Pivec, Jiri and Riemer, Felix and Worm, Steven and Bourgouin, Alexandra},
  title = {Dosimetric and temporal beam characterization of individual pulses in FLASH radiotherapy using Timepix3 pixelated detector placed out-of-field},
  journal = {Physica Medica},
  year = {2025},
  doi = {10.1016/j.ejmp.2024.104872}
}
Kostenlos starten →