Fachartikel in der Zeitschrift Australasian Physical & Engineering Sciences in Medicine, online erschienen am 06.04.2016. Verfasst von Takayuki Shibutani und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa, 920-0942, …. Hauptthemen laut MEDLINE: Myocardial Perfusion Imaging, Tomography, Emission-Computed, Single-Photon. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Myocardial perfusion single photon emission computed tomography (SPECT) is typically subject to a variation in image quality due to the use of different acquisition protocols, image reconstruction parameters and image display settings by each institution. One of the principal image reconstruction parameters is the Butterworth filter cut-off frequency, a parameter strongly affecting the quality of myocardial images. The objective of this study was to formulate a flowchart for the determination of the optimal parameters of the Butterworth filter for filtered back projection (FBP), ordered subset expectation maximization (OSEM) and collimator-detector response compensation OSEM (CDR-OSEM) methods using the evaluation system of the myocardial image based on technical grounds phantom. SPECT studies were acquired for seven simulated defects where the average counts of the normal myocardial components of 45° left anterior oblique projections were approximately 10-120 counts/pixel. These SPECT images were then reconstructed by FBP, OSEM and CDR-OSEM methods. Visual and quantitative assessment of short axis images were performed for the defect and normal parts. Finally, we formulated a flowchart indicating the optimal image processing procedure for SPECT images. Correlation between normal myocardial counts and the optimal cut-off frequency could be represented as a regression expression, which had high or medium coefficient of determination. We formulated the flowchart in order to optimize the image reconstruction parameters based on a comprehensive assessment, which enabled us to perform objectively processing. Furthermore, the usefulness of image reconstruction using the flowchart was demonstrated by a clinical case.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Myocardial Perfusion ImagingTomography, Emission-Computed, Single-PhotonAged, 80 and overAlgorithmsFemaleHumansImage Processing, Computer-AssistedPhantoms, ImagingTechnetium

Stichwörter der Autor:innen

Butterworth filterCut-off frequencyFlowchartMyocardial perfusion SPECTOptimizationStandardization

Substanzen

Technetium

Autor:innen und Institutionen

  • Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa, 920-0942, Japan.
  • Department of Biotracer Medicine, Graduate School of Medical Science, Kanazawa University, Kanazawa, Japan.
  • Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa, 920-0942, Japan. onoguchi@staff.kanazawa-u.ac.jp.
  • Department of Radiological Technology, Kishiwada City Hospital, 1001 Gakuhara-cho, Kishiwada, Osaka, Japan.
  • Department of Radiological Technology, Higashiosaka City General Hospital, 3-4-5 Nishiiwata, Higashiosaka, Osaka, Japan.
  • Department of Radiological Technology, Osaka Medical Center for Cancer and Cardiovascular Diseases, 1-3-3 Nakamichi, Higashinariku, Osaka, Japan.

Zitieren

APA

Shibutani, T., Onoguchi, M., Yamada, T., Kamida, H., Kunishita, K., Hayashi, Y., Nakajima, T., & Kinuya, S. (2016). Optimization of the filter parameters in 99mTc myocardial perfusion SPECT studies: the formulation of flowchart. Australasian Physical & Engineering Sciences in Medicine, 39(2), 571-581. https://doi.org/10.1007/s13246-016-0433-2

Vancouver

Shibutani T, Onoguchi M, Yamada T, Kamida H, Kunishita K, Hayashi Y, et al. Optimization of the filter parameters in 99mTc myocardial perfusion SPECT studies: the formulation of flowchart. Australasian Physical & Engineering Sciences in Medicine. 2016;39(2):571-581. doi:10.1007/s13246-016-0433-2

BibTeX
@article{Shibutani2016,
  author = {Shibutani, Takayuki and Onoguchi, Masahisa and Yamada, Tomoki and Kamida, Hiroki and Kunishita, Kohei and Hayashi, Yuuki and Nakajima, Tadashi and Kinuya, Seigo},
  title = {Optimization of the filter parameters in 99mTc myocardial perfusion SPECT studies: the formulation of flowchart},
  journal = {Australasian Physical & Engineering Sciences in Medicine},
  year = {2016},
  volume = {39},
  number = {2},
  pages = {571--581},
  doi = {10.1007/s13246-016-0433-2}
}
Kostenlos starten →