Evaluation of the usefulness of the masking on un-smoothed image method in 201Tl myocardial perfusion SPECT
Radiological Physics and Technology · 2025
DOI: 10.1007/s12194-025-00959-2 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift Radiological Physics and Technology, 2025. Verfasst von Ryuichi Miyajima und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, NHO Nagasaki Medical Center, 2-1001-1, Kubara, Omura, Nagasaki, 856-8562, Japan. miyajima.ryuichi.wk@mail.hosp.go.jp. Hauptthemen laut MEDLINE: Tomography, Emission-Computed, Single-Photon, Myocardial Perfusion Imaging, Thallium Radioisotopes, Image Processing, Computer-Assisted. Die Arbeit nennt 12 Literaturangaben. Gefördert von: PDRadiopharma.
Abstract (Originalsprache)
In 201Tl myocardial perfusion single-photon emission computed tomography (SPECT), gastric wall uptake can impact the inferior wall. This study aimed to evaluate the effectiveness and usefulness of the masking on un-smoothed image (MUS) method for 201Tl myocardial perfusion SPECT. A hemispherical gastric wall phantom was created to simulate the gastric fundus located closest to the myocardium, and the activity was enclosed to achieve an SPECT count ratio against the myocardium equivalent to that observed in clinical practice. The minimum values of the defect chip in the circumferential profile curve were compared for six SPECT count ratios and seven gap distances. In the conventional method, increasing SPECT count ratios or gap distances interfered with myocardial perfusion SPECT evaluation. Artifacts were less apparent when the MUS method was applied. The MUS method effectively suppressed the gastric wall uptake on 201Tl myocardial perfusion SPECT.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, NHO Nagasaki Medical Center, 2-1001-1, Kubara, Omura, Nagasaki, 856-8562, Japan. miyajima.ryuichi.wk@mail.hosp.go.jp.
- Department of Radiology, NHO Fukuokahigashi Medical Center, 1-1-1, Chidori, Koga, Fukuoka, 811-3113, Japan.
- PDRadiopharma Inc., Kanematsu Bld., 2-14-1, Kyobashi, Chuo, Tokyo, 104-0031, Japan.
- Department of Cardiovascular Internal Medicine, NHO Kagoshima Medical Center, 8-1, Shiroyamacho, Kagoshima, Kagoshima, 892-0853, Japan.
Förderung
- PDRadiopharma
Zitieren
APA
Miyajima, R., Ueno, R., Ichino, R., Teraoka, S., Yasushi, I., & Sonoda, M. (2025). Evaluation of the usefulness of the masking on un-smoothed image method in 201Tl myocardial perfusion SPECT. Radiological Physics and Technology. https://doi.org/10.1007/s12194-025-00959-2
Vancouver
Miyajima R, Ueno R, Ichino R, Teraoka S, Yasushi I, Sonoda M. Evaluation of the usefulness of the masking on un-smoothed image method in 201Tl myocardial perfusion SPECT. Radiological Physics and Technology. 2025. doi:10.1007/s12194-025-00959-2
BibTeX
@article{Miyajima2025,
author = {Miyajima, Ryuichi and Ueno, Ryo and Ichino, Ryosuke and Teraoka, Satomi and Yasushi, Ishikawa and Sonoda, Masahiro},
title = {Evaluation of the usefulness of the masking on un-smoothed image method in 201Tl myocardial perfusion SPECT},
journal = {Radiological Physics and Technology},
year = {2025},
doi = {10.1007/s12194-025-00959-2}
}