EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Improving ungated steady‐state cardiac perfusion using transition bands

Jason K Mendes iD, Johnathan V Le iD, Andrew E Arai, Ravi Ranjan, Edward V R DiBella, Ganesh Adluru

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30467 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Jason K Mendes und 5 weiteren Autor:innen. Beteiligte Einrichtung: Utah Center for Advanced Imaging Research, Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, USA. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted, Myocardial Perfusion Imaging, Heart, Coronary Circulation. Die Arbeit nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NHLBI NIH HHS, National Heart, Lung, and Blood Institute (NHLBI), NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Although gated first‐pass contrast‐enhanced sequences are the clinical standard for cardiovascular MR perfusion, some patient conditions necessitate using ungated steady‐state sequences. However, through‐plane cardiac motion and blood flow into the left ventricle can disrupt the magnetization steady state of the tissue, and perfusion quantification based on a steady‐state assumption will contain errors. The tissue magnetization steady‐state disruption can be eliminated with a proposed sequence modification that simultaneously excites transition bands with no change in the sequence resolution or timing parameters. Theory and Methods The proposed sequence modification simultaneously excites two transition bands adjacent to the imaged region. The transition bands experience the same consistent excitation history as the imaged slices. Thus, any tissue that moves into an imaged slice location from a transition band location will not disrupt the magnetization steady state. Gradient dephasing and radiofrequency spoiling are used to null the transition band signal so that it does not contribute to the reconstructed images. Transition bands were added to a two‐dimensional ungated steady‐state radial FLASH (fast low‐angle shot) sequence with simultaneous multiband imaging on a PRISMA 3T MRI scanner. Phantom, normal canine, and human subject data are presented.

Results

Transition bands reduce the amount of tissue magnetization disruption to the steady state without adding artifacts to the imaged slices. Myocardial blood flow maps from a selected normal canine study and a normal human subject show good uniformity and consistency to literature values for all slices. Perfusion estimates with the proposed method also demonstrate good consistency with saturation‐recovery methods commonly used for myocardial perfusion imaging.

Conclusion

We have demonstrated that the proposed transition bands can reduce quantification errors resulting from blood flow into the left ventricle and through‐plane cardiac and respiratory motion. There is no loss of image‐acquisition efficiency, and temporal resolution is unchanged with this technique.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Image Processing, Computer-AssistedMyocardial Perfusion ImagingHeartCoronary CirculationMagnetic Resonance ImagingMagnetic Resonance AngiographyHumansAlgorithmsPhantoms, ImagingAnimalsDogsHeart Ventricles

Stichwörter der Autor:innen

arterial input functioncardiac perfusionungated perfusion

Autor:innen und Institutionen

  • Utah Center for Advanced Imaging Research, Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, USA.
  • Department of Biomedical Engineering, University of Utah, Salt Lake City, Utah, USA.
  • Division of Cardiovascular Medicine, University of Utah, Salt Lake City, Utah, USA.

ORCID-Profile: Jason K Mendes, Johnathan V Le

Förderung

  • NHLBI NIH HHS
  • National Heart, Lung, and Blood Institute (NHLBI)
  • NIH HHS

Zitieren

APA

Mendes, J. K., Le, J. V., Arai, A. E., Ranjan, R., DiBella, E. V. R., & Adluru, G. (2025). Improving ungated steady‐state cardiac perfusion using transition bands. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30467

Vancouver

Mendes JK, Le JV, Arai AE, Ranjan R, DiBella EVR, Adluru G. Improving ungated steady‐state cardiac perfusion using transition bands. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30467

BibTeX
@article{Mendes2025,
  author = {Mendes, Jason K and Le, Johnathan V and Arai, Andrew E and Ranjan, Ravi and DiBella, Edward V R and Adluru, Ganesh},
  title = {Improving ungated steady‐state cardiac perfusion using transition bands},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30467}
}
Kostenlos starten →