3D quantitative myocardial perfusion imaging with hyperpolarized HP001(bis‐1,1‐(hydroxymethyl)‐[1‐ 13 C]cyclopropane‐d8): Application of gradient echo and balanced SSFP sequences
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30320 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Yupeng Zhao und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Health Technology, Technical University of Denmark, Kgs. Lyngby, Denmark. Hauptthemen laut MEDLINE: Myocardial Perfusion Imaging, Phantoms, Imaging, Imaging, Three-Dimensional. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The European Union's Horizon 2020 Research and Innovation Program.
Abstract (Originalsprache)
Purpose
This study aims to show the viability of conducting three‐dimensional (3D) myocardial perfusion quantification covering the entire heart using both GRE and bSSFP sequences with hyperpolarized HP001.
Methods
A GRE sequence and a bSSFP sequence, both with a stack‐of‐spirals readout, were designed and applied to three pigs. The images were reconstructed using C coil sensitivity maps measured in a phantom experiment. Perfusion was quantified using a constrained decomposition method, and the estimated rest/stress perfusion values from C GRE/bSSFP and Dynamic contrast‐enhanced MRI (DCE‐MRI) were individually analyzed through histograms and the mean perfusion values were compared with reference values obtained from PET(O‐water). The Myocardial Perfusion Reserve Index (MPRI) was estimated for C GRE/bSSFP and DCE‐MRI and compared with the reference values.
Results
Perfusion values, estimated by both DCE and C MRI, were found to be lower than reference values. However, DCE‐MRI's estimated perfusion values were closer to the reference values than those obtained from C MRI. In the case of MPRI estimation, the C estimated MPRI values (GRE/bSSFP: 2.3/2.0) more closely align with the literature value (around 3) than the DCE estimated MPRI value (1.6).
Conclusion
This study demonstrated the feasibility of 3D whole‐heart myocardial perfusion quantification using hyperpolarized HP001 with both GRE and bSSFP sequences. The C perfusion measurements underestimated perfusion values compared to the O PET literature value, while the C estimated MPRI value aligned better with the literature. This preliminary result indicates C imaging may more accurately estimate MPRI values compared to DCE‐MRI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Health Technology, Technical University of Denmark, Kgs. Lyngby, Denmark.
- MR Research Centre, Aarhus University, Aarhus, Denmark.
- Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Hvidovre, Hvidovre, Denmark.
ORCID-Profile: Yupeng Zhao, Rie Beck Olin, Esben Søvsø Szocska Hansen, Christoffer Laustsen, Lars G Hanson, Jan Henrik Ardenkjær-Larsen
Förderung
- The European Union's Horizon 2020 Research and Innovation Program
Zitieren
APA
Zhao, Y., Olin, R. B., Hansen, E. S. S., Laustsen, C., Hanson, L. G., & Ardenkjær-Larsen, J. H. (2025). 3D quantitative myocardial perfusion imaging with hyperpolarized HP001(bis‐1,1‐(hydroxymethyl)‐[1‐ 13 C]cyclopropane‐d8): Application of gradient echo and balanced SSFP sequences. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30320
Vancouver
Zhao Y, Olin RB, Hansen ESS, Laustsen C, Hanson LG, Ardenkjær-Larsen JH. 3D quantitative myocardial perfusion imaging with hyperpolarized HP001(bis‐1,1‐(hydroxymethyl)‐[1‐ 13 C]cyclopropane‐d8): Application of gradient echo and balanced SSFP sequences. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30320
BibTeX
@article{Zhao2025,
author = {Zhao, Yupeng and Olin, Rie Beck and Hansen, Esben Søvsø Szocska and Laustsen, Christoffer and Hanson, Lars G and Ardenkjær-Larsen, Jan Henrik},
title = {3D quantitative myocardial perfusion imaging with hyperpolarized HP001(bis‐1,1‐(hydroxymethyl)‐[1‐ 13 C]cyclopropane‐d8): Application of gradient echo and balanced SSFP sequences},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30320}
}
EUVIMED