EUVIMEDEUVIMED entdecken
VergleichsstudieEvaluationsstudie

Comparative evaluation of feature-based and intensity-based algorithms for dosimetric registration in radiotherapy quality assurance using electronic portal imaging devices

Meryeme Bellahsaouia, Ibtissam Zidouh, Ouadie Kabach, Deiaa Elaarabi, Elmahjoub Chakir

Radiological Physics and Technology · 2026

DOI: 10.1007/s12194-026-01031-3 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Radiological Physics and Technology, 2026. Verfasst von Meryeme Bellahsaouia und 4 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Physics Materials and Subatomic, Ibn Tofail University, Kenitra, Morocco. meryeme.bellahsaouia@uit.ac.ma. Hauptthemen laut MEDLINE: Algorithms, Quality Assurance, Health Care, Radiometry, Radiotherapy, Intensity-Modulated. Die Arbeit nennt 34 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To evaluate image registration as a quantitative alternative to the gamma index for VMAT patient-specific quality assurance and to benchmark feature-based against intensity-based registration algorithms. We retrospectively analyzed 93 EPID-verified VMAT arcs using five registration algorithms: three feature-based (SIFT, Thin-Plate Splines, CONCORD) and two intensity-based (B-spline, Demons). We assessed the ability of each algorithm to align absolute dose distributions on a common coordinate grid. Dosimetric agreement was quantified using a dual-parameter metric combining linear regression slope (tolerance 95–105%) and the coefficient of determination [Formula: see text] Standard gamma analysis (3%/3 mm, 90% passing rate) served as the clinical reference. Agreement with gamma-based classification was evaluated using Cohen’s kappa [Formula: see text]. Feature-based methods significantly outperformed intensity-based models. The dose-specific CONCORD algorithm achieved the highest initial agreement with gamma analysis [Formula: see text]. Application of the dual-parameter metric further enhanced diagnostic specificity; specifically, CONCORD’s agreement improved to [Formula: see text] with 95.7% accuracy. In contrast, intensity-based deformable models exhibited poor performance and high false-negative rates. This behavior introduces non-physical dose warping that obscures clinically relevant delivery errors. Registration-based dose comparison offers a robust, quantitative alternative to the gamma index. By utilizing a global affine transformation and dose-specific topological features, the CONCORD algorithm effectively detects localized and systematic discrepancies without the error-masking risks inherent in generic deformable registration. This framework aligns with AAPM TG-307 objectives, offering a more granular and physically intuitive assessment of VMAT delivery fidelity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AlgorithmsQuality Assurance, Health CareRadiometryRadiotherapy, Intensity-ModulatedImage Processing, Computer-AssistedElectrical Equipment and SuppliesHumansRadiotherapy DosageRadiotherapy Planning, Computer-Assisted

Stichwörter der Autor:innen

Deformable image registrationDose distribution comparisonGamma indexImage registrationRadiotherapy quality assurance

Autor:innen und Institutionen

  • Laboratory of Physics Materials and Subatomic, Ibn Tofail University, Kenitra, Morocco. meryeme.bellahsaouia@uit.ac.ma.
  • Laboratory of Physics Materials and Subatomic, Ibn Tofail University, Kenitra, Morocco.

Zitieren

APA

Bellahsaouia, M., Zidouh, I., Kabach, O., Elaarabi, D., & Chakir, E. (2026). Comparative evaluation of feature-based and intensity-based algorithms for dosimetric registration in radiotherapy quality assurance using electronic portal imaging devices. Radiological Physics and Technology. https://doi.org/10.1007/s12194-026-01031-3

Vancouver

Bellahsaouia M, Zidouh I, Kabach O, Elaarabi D, Chakir E. Comparative evaluation of feature-based and intensity-based algorithms for dosimetric registration in radiotherapy quality assurance using electronic portal imaging devices. Radiological Physics and Technology. 2026. doi:10.1007/s12194-026-01031-3

BibTeX
@article{Bellahsaouia2026,
  author = {Bellahsaouia, Meryeme and Zidouh, Ibtissam and Kabach, Ouadie and Elaarabi, Deiaa and Chakir, Elmahjoub},
  title = {Comparative evaluation of feature-based and intensity-based algorithms for dosimetric registration in radiotherapy quality assurance using electronic portal imaging devices},
  journal = {Radiological Physics and Technology},
  year = {2026},
  doi = {10.1007/s12194-026-01031-3}
}
Kostenlos starten →