Myelin water imaging of in vivo and ex vivo human brains using multi‐echo gradient echo at 3 T and 7 T
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30310 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Guojun Xu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, College of Biomedical Engineering and Instr…. Hauptthemen laut MEDLINE: Myelin Sheath, Brain, Magnetic Resonance Imaging. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 50 Literaturangaben. Gefördert von: National Key Research and Development Program of China, Science and Technology Department of Zhejiang Province, Ministry of Science and Technology of the People's Republic of China.
Abstract (Originalsprache)
Purpose
To compare the myelin water fraction (MWF) measurements between 3 T and 7 T and between in vivo and ex vivo human brains, and to investigate the relationship between multi‐echo gradient‐echo (mGRE)‐based 3D MWF and myelin content using histological staining, which has not been validated in the human brain.
Methods
In this study, we performed 3D mGRE‐based MWF measurements on five ex vivo human brain hemispheres and five healthy volunteers at 3 T and 7 T with 1 mm isotropic resolution. The data were fitted with the based on a three compartment complex‐valued model to estimate MWF. We obtained myelin basic protein (MBP) staining from two tissue blocks and co‐registered the MWF map and histology image for voxel‐wise correlation between the two.
Results
The MWF values measured from 7 T were overall higher than 7 T, but data between the two field strength demonstrated high correlations both in vivo ( r = 0.88) and ex vivo ( r = 0.83) across 19 white matter regions. Moreover, the MWF measurements showed a good agreement between in vivo and ex vivo assessments at 3 T ( r = 0.61) and 7 T ( r = 0.54). Based on MBP staining, the MWF values exhibited strong positive correlations with myelin content on both 3 T ( r = 0.68 and r = 0.78 for the two tissue blocks) and 7 T ( r = 0.64 and r = 0.82 for the two tissue blocks).
Conclusion
The findings demonstrated that the mGRE‐based MWF mapping can be used to quantify myelin content in the human brain, despite the field‐strength dependency of the measurements.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, College of Biomedical Engineering and Instrument Science, Zhejiang University, Hangzhou, China.
- Children's Hospital, National Clinical Research Center for Child Health, Zhejiang University School of Medicine, Hangzhou, China.
- China Brain Bank and Department of Neurology in Second Affiliated Hospital, Key Laboratory of Medical Neurobiology of Zhejiang Province, and Department of Neurobiology, Zhejiang University School of Medicine, Hangzhou,…
- Department of Pathology, The First Affiliated Hospital and School of Medicine, Zhejiang University, Hangzhou, China.
ORCID-Profile: Dan Wu
Förderung
- National Key Research and Development Program of China
- Science and Technology Department of Zhejiang Province
- Ministry of Science and Technology of the People's Republic of China
- Young Investigator Program of United Imaging
- National Natural Science Foundation of China
Zitieren
APA
Xu, G., Zhao, Z., Zhu, Q., Zhu, K., Zhang, J., & Wu, D. (2025). Myelin water imaging of in vivo and ex vivo human brains using multi‐echo gradient echo at 3 T and 7 T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30310
Vancouver
Xu G, Zhao Z, Zhu Q, Zhu K, Zhang J, Wu D. Myelin water imaging of in vivo and ex vivo human brains using multi‐echo gradient echo at 3 T and 7 T. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30310
BibTeX
@article{Xu2025,
author = {Xu, Guojun and Zhao, Zhiyong and Zhu, Qinfeng and Zhu, Keqing and Zhang, Jing and Wu, Dan},
title = {Myelin water imaging of in vivo and ex vivo human brains using multi‐echo gradient echo at 3 T and 7 T},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30310}
}
EUVIMED