SNR ‐Efficient Inhomogeneous Magnetization Transfer ( ihMT ) for Clinical Applications at 7 T
Magnetic Resonance in Medicine · 2026-09 · 96 (3) · 1162-1177
DOI: 10.1002/mrm.70419 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 11.05.2026. Verfasst von Timothy Anderson und 8 weiteren Autor:innen. Beteiligte Einrichtung: Aix Marseille Univ, CNRS, CRMBM, Marseille, France. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Image Processing, Computer-Assisted, Brain. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: A*MIDEX, Agence Nationale de la Recherche, France Life Imaging.
Abstract (Originalsprache)
Purpose
Inhomogeneous MT (ihMT) is an MRI modality sensitive to Myelin, the lipid‐rich membrane surrounding the axons. A novel ihMT saturation strategy and its associated correction at UHF are proposed. The aim is to generate a strong ihMT effect within a clinically compatible scan time while complying with SAR constraints at 7 T.
Methods
The MT preparation module of the proposed approach was shortened, reducing power deposition and allowing for shorter scan time while maximizing SNR efficiency. Optimization of the sequence was validated on (2 mm iso.) on a 7 T clinical scanner. Example high resolution images were acquired (1–1.4 mm iso.). Model‐based corrections were applied and their impact on ihMT quantification was studied. Numerical simulations and error quantifications were performed to complement experimental data.
Results
Fewer bursts () of cosine‐modulated MT preparation pulses () performed at maximal yielded strong ihMT signal with better SNR efficiency as compared to previously proposed long saturation trains (). correction showed a reliability range () which challenged applicability in strong hypo‐intense areas. High resolution acquisitions showed acceptable SNR () for resolutions down to 1 mm iso., enabling studies of fine structures (e.g., deep gray nuclei) with added specificity provided by ihMT. Conclusion ihMT applications at 7 T are enabled. While whole‐brain imaging requires further work to compensate for inhomogeneities, localized applications (e.g., Thalamus) are immediately feasible within clinically compatible scan time (< min). Similar sequence improvements are expected at lower field strengths (e.g., ).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France.
- APHM, Hôpital Universitaire Timone, CEMEREM, Marseille, France.
- Siemens Healthcare SAS, Courbevoie, France.
- Radiology, Division of MR Research, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.
ORCID-Profile: Timothy Anderson, Lucas Soustelle, Thomas Troalen, Gopal Varma, Olivier M Girard
Förderung
- A*MIDEX
- Agence Nationale de la Recherche
- France Life Imaging
- France Sclérose en Plaques
Zitieren
APA
Anderson, T., Wallstein, N., Soustelle, L., Troalen, T., Varma, G., Alsop, D. C., Guye, M., Duhamel, G., & Girard, O. M. (2026). SNR ‐Efficient Inhomogeneous Magnetization Transfer ( ihMT ) for Clinical Applications at 7 T. Magnetic Resonance in Medicine, 96(3), 1162-1177. https://doi.org/10.1002/mrm.70419
Vancouver
Anderson T, Wallstein N, Soustelle L, Troalen T, Varma G, Alsop DC, et al. SNR ‐Efficient Inhomogeneous Magnetization Transfer ( ihMT ) for Clinical Applications at 7 T. Magnetic Resonance in Medicine. 2026;96(3):1162-1177. doi:10.1002/mrm.70419
BibTeX
@article{Anderson2026,
author = {Anderson, Timothy and Wallstein, Niklas and Soustelle, Lucas and Troalen, Thomas and Varma, Gopal and Alsop, David C and Guye, Maxime and Duhamel, Guillaume and Girard, Olivier M},
title = {SNR ‐Efficient Inhomogeneous Magnetization Transfer ( ihMT ) for Clinical Applications at 7 T},
journal = {Magnetic Resonance in Medicine},
year = {2026},
volume = {96},
number = {3},
pages = {1162--1177},
doi = {10.1002/mrm.70419}
}
EUVIMED