Effect of cement type on vertical marginal discrepancy and residual excess cement in screwmentable and cementable implant-supported monolithic zirconia crowns

Pınar Yıldız, Göknil Alkan Demetoğlu, Esra Talay Çevlik

Odontology · 2024-10 · 112 (4) · 1221-1230

DOI: 10.1007/s10266-024-00938-w ↗

Kurz gefasst

Fachartikel in der Zeitschrift Odontology, online erschienen am 18.04.2024. Verfasst von Pınar Yıldız und 2 weiteren Autor:innen. Beteiligte Einrichtung: Nimet Bayraktar Oral and Dental Health Center, Hürriyet Mah. Kılıçkaya Cad., Kayseri, Türkiye. dentistpinar@hotmail.com. Hauptthemen laut MEDLINE: Zirconium, Crowns, Dental Cements, Dental Prosthesis, Implant-Supported. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 43 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The purpose of this study was to investigate the vertical marginal discrepancy (VMD) and residual excess cement (REC) of cementable and screwmentable monolithic zirconia crowns cemented with different types of cement. Abutments were attached to 40 implant analogues. Crowns were created using computer-aided design/computer-aided manufacturing technology from monolithic zirconia blocks, either with or without a screw access hole (SAC). Crowns created both ways were split into two groups and cemented with resin and zinc polycarboxylate cement under a 5-kg weight. VMD and REC values were evaluated using an X20 zoom stereomicroscope. Data were analysed using two-way ANOVA and the Bonferroni test. According to the two-way ANOVA results, REC measurements differed significantly in the crown design and cement groups. However, whilst VMD values were significantly different in both crown design groups, there was no significant difference in the cement groups. According to the Bonferroni test results, the highest REC (157.241 ± 44.29 µm) and VMD (68.052 ± 16.19 µm) values were found in the crowns without SAC and cemented with zinc polycarboxylate. Screwmentable crowns are more effective than cementable crowns in reducing REC and VMD. Whilst polycarboxylate cement reduces VMD in screwmentable crowns, resin cement is more suitable for cementable crowns.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ZirconiumCrownsDental CementsDental Prosthesis, Implant-SupportedComputer-Aided DesignDental Marginal AdaptationCementationMaterials TestingDental Prosthesis DesignDental AbutmentsResin CementsHumansPolycarboxylate Cement

Stichwörter der Autor:innen

CAD/CAMCementableDental implantationMarginal adaptationScrewmentable

Substanzen

Zirconiumzirconium oxideDental CementsResin CementsPolycarboxylate Cement

Autor:innen und Institutionen

  • Nimet Bayraktar Oral and Dental Health Center, Hürriyet Mah. Kılıçkaya Cad., Kayseri, Türkiye. dentistpinar@hotmail.com.
  • Department of Prosthodontics, Faculty of Dentistry, Aydın Adnan Menderes University, Hasanefendi Mahallesi, Hastane Cd. No:1, Aydın, Türkiye.

Zitieren

APA

Yıldız, P., Alkan Demetoğlu, G., & Talay Çevlik, E. (2024). Effect of cement type on vertical marginal discrepancy and residual excess cement in screwmentable and cementable implant-supported monolithic zirconia crowns. Odontology, 112(4), 1221-1230. https://doi.org/10.1007/s10266-024-00938-w

Vancouver

Yıldız P, Alkan Demetoğlu G, Talay Çevlik E. Effect of cement type on vertical marginal discrepancy and residual excess cement in screwmentable and cementable implant-supported monolithic zirconia crowns. Odontology. 2024;112(4):1221-1230. doi:10.1007/s10266-024-00938-w

BibTeX
@article{Yldz2024,
  author = {Yıldız, Pınar and Alkan Demetoğlu, Göknil and Talay Çevlik, Esra},
  title = {Effect of cement type on vertical marginal discrepancy and residual excess cement in screwmentable and cementable implant-supported monolithic zirconia crowns},
  journal = {Odontology},
  year = {2024},
  volume = {112},
  number = {4},
  pages = {1221--1230},
  doi = {10.1007/s10266-024-00938-w}
}
Kostenlos starten →