Marginal Misfit Assessment in Common Restorative Materials for Cement‐Retained Fixed Implant Prostheses: An In Vitro Comparative Study
Clinical and Experimental Dental Research · 2026
DOI: 10.1002/cre2.70318 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Clinical and Experimental Dental Research, 2026. Verfasst von Pedro Diaz und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Conservative Dentistry and Bucofacial Prostheses, Faculty of Odontology, Complutense University of Madrid, Madrid, Spain. Hauptthemen laut MEDLINE: Crowns, Dental Prosthesis, Implant-Supported, Dental Marginal Adaptation, Dental Materials. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 71 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Complutense University of Madrid (UCM), Zimmer Dental Iberica S.L.U, Phibo Dental Solutions S.L..
Abstract (Originalsprache)
Objectives
To assess the vertical discrepancy at the abutment–crown interface (ACI) for cement‐retained crowns fabricated from three commonly used restorative materials across implants featuring external and internal connections. Materials and Methods A total of 30 implants with external (EC) and internal (IC) connections were included in this study. Each implant received a prefabricated titanium abutment, which was randomly attached using the torque recommended by the respective manufacturers. Three types of restorative materials—metal‐ceramic (MC), monolithic zirconia (MZ), and veneered zirconia (VZ)—were used to fabricate the crowns for each connection type and cemented to their respective abutments. Following 6000 cycles of thermal cycling between 5°C and 55°C, the vertical marginal misfit was evaluated using scanning electron microscopy. Data were statistically analyzed using repeated‐measures ANOVA, followed by Bonferroni post‐hoc test and paired t ‐test.
Results
The lowest marginal misfit was recorded for VZ restorations. Although the IC group showed lower mean misfit values compared to the EC group, this difference was not statistically significant ( p = 0.980). Significant differences were found in the IC group between MZ and VZ ( p = 0.016) and between MC and VZ ( p = 0.035). Mean misfit values (µm) for each material were as follows: VZ = 18.7 (SD = 4.5), MZ = 42.2 (SD = 8.1), and MC = 39.9 (SD = 7.4).
Conclusions
Cement‐retained veneered zirconia restorations demonstrated less vertical ACI misfit compared to metal‐ceramic and monolithic zirconia restorations. The connection configuration did not influence the marginal misfit. All measured misfit values were below 50 µm.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Conservative Dentistry and Bucofacial Prostheses, Faculty of Odontology, Complutense University of Madrid, Madrid, Spain.
- Department of Clinic Grade Dentistry, Faculty of Odontology, European University of Madrid, Madrid, Spain.
- Department of Research Analytics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India.
- Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran.
ORCID-Profile: Pedro Diaz, Seyed Ali Mosaddad, Celia Tobar, Maria J Suarez
Förderung
- Complutense University of Madrid (UCM)
- Zimmer Dental Iberica S.L.U
- Phibo Dental Solutions S.L.
Zitieren
APA
Diaz, P., Miegimolle, B., Martin, A., Mosaddad, S. A., Tobar, C., & Suarez, M. J. (2026). Marginal Misfit Assessment in Common Restorative Materials for Cement‐Retained Fixed Implant Prostheses: An In Vitro Comparative Study. Clinical and Experimental Dental Research. https://doi.org/10.1002/cre2.70318
Vancouver
Diaz P, Miegimolle B, Martin A, Mosaddad SA, Tobar C, Suarez MJ. Marginal Misfit Assessment in Common Restorative Materials for Cement‐Retained Fixed Implant Prostheses: An In Vitro Comparative Study. Clinical and Experimental Dental Research. 2026. doi:10.1002/cre2.70318
BibTeX
@article{Diaz2026,
author = {Diaz, Pedro and Miegimolle, Barbara and Martin, Antonio and Mosaddad, Seyed Ali and Tobar, Celia and Suarez, Maria J},
title = {Marginal Misfit Assessment in Common Restorative Materials for Cement‐Retained Fixed Implant Prostheses: An In Vitro Comparative Study},
journal = {Clinical and Experimental Dental Research},
year = {2026},
doi = {10.1002/cre2.70318}
}