Deflection of occlusal splints under bruxism-like conditions: An exploratory in vitro investigation
Clinical Oral Investigations · 19.06.2026 · 30 (7)
DOI: 10.1007/s00784-026-06965-x ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Oral Investigations, online erschienen am 19.06.2026. Verfasst von Cordula Leonie Merle und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthetic Dentistry, UKR University Hospital Regensburg, 93053, Regensburg, Bavaria, Germany. cordula.merle@ukr.de. Hauptthemen laut MEDLINE: Occlusal Splints, Bruxism. Die Arbeit nennt 37 Literaturangaben. Gefördert von: Some materials for this study were provided by the individual manufacturers without any influence on study design, data analysis, or interpretation..
Abstract (Originalsprache)
Objective
Occlusal splints are common part of bruxism management to reduce occlusal forces. This preliminary study investigates in vitro the deflection of occlusal splint materials. Materials and methods Two occlusal splints per material were fabricated by casting (Palapress vario), thermoforming (Erkodur 1.0 mm and 1.5 mm), milling (Bio Splint P HI, Bio Splint C, ClearSplint), and 3D printing (LuxaPrint Ortho Plus, 0° and 45° orientation). Each splint was applied to a functional dental model featuring movable plastic teeth. The right upper incisor, canine, and second premolar were loaded up to 50 N on occlusal and buccal sides using a universal testing machine (Z010, Zwick; four measurements). Statistical analysis used Kruskal–Wallis and Dunn’s test with Bonferroni correction (α = 0.05).
Results
Mean deflection of the tooth-splint-system ranged from 0.8 mm to 2.7 mm. Significant differences between the materials were detected ( p < 0.001), with the highest values for Erkodur 1.0 mm and ClearSplint and the lowest for Bio Splint P HI and Erkodur 1.5 mm. No significant differences were observed between the two print orientations of LuxaPrint Ortho Plus.
Conclusions
This preliminary study demonstrates material-dependent differences in the deflection of occlusal splints under load. Clinically oriented test setups may provide valuable insight for evidence-based material selection in bruxism management.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Prosthetic Dentistry, UKR University Hospital Regensburg, 93053, Regensburg, Bavaria, Germany. cordula.merle@ukr.de.
- Department of Prosthetic Dentistry, UKR University Hospital Regensburg, 93053, Regensburg, Bavaria, Germany.
Förderung
- Some materials for this study were provided by the individual manufacturers without any influence on study design, data analysis, or interpretation.
Zitieren
APA
Merle, C. L., Rauch, A., Wulff, J., Schmidt, M. B., & Rosentritt, M. (2026). Deflection of occlusal splints under bruxism-like conditions: An exploratory in vitro investigation. Clinical Oral Investigations, 30(7). https://doi.org/10.1007/s00784-026-06965-x
Vancouver
Merle CL, Rauch A, Wulff J, Schmidt MB, Rosentritt M. Deflection of occlusal splints under bruxism-like conditions: An exploratory in vitro investigation. Clinical Oral Investigations. 2026;30(7). doi:10.1007/s00784-026-06965-x
BibTeX
@article{Merle2026,
author = {Merle, Cordula Leonie and Rauch, Angelika and Wulff, Johann and Schmidt, Michael Benno and Rosentritt, Martin},
title = {Deflection of occlusal splints under bruxism-like conditions: An exploratory in vitro investigation},
journal = {Clinical Oral Investigations},
year = {2026},
volume = {30},
number = {7},
doi = {10.1007/s00784-026-06965-x}
}
EUVIMED