Comparison of wear behavior of occlusal device materials manufactured by different processes
The Journal of Prosthetic Dentistry · 2026-03 · 135 (3) · 614.e1-614.e7
DOI: 10.1016/j.prosdent.2025.10.040 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Journal of Prosthetic Dentistry, 2026-03. Verfasst von Catherine Arreaza und 4 weiteren Autor:innen. Beteiligte Einrichtung: Clinical Assistant Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio. Elect…. Hauptthemen laut MEDLINE: Dental Restoration Wear, Dental Materials, Occlusal Splints. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Occlusal devices have been used for therapeutic and diagnostic purposes. Although their effectiveness in preventing tooth wear has been reported, research regarding the wear of the occlusal device when opposing different materials is lacking. PURPOSE: The purpose of this in vitro study was to measure and compare the volumetric wear of conventionally processed, milled, and 3-dimensionally (3D) printed occlusal device materials when opposed by human enamel, lithium disilicate, and 4 mol% yttria-stabilized zirconia. MATERIAL AND METHODS: Milled polymethyl methacrylate (ProArt CAD Splint; Ivoclar AG), printed resin (Next Dent Ortho Rigid), and conventional heat-polymerized polymethyl methacrylate (Vitacrilic Clear; Fricke International, Inc) were tested. Fifteen Ø14×2-mm disk-shaped specimens were fabricated from each manufacturing process. Each material group was divided into 3 groups of 5 specimens and tested against each of the 3 antagonist materials, human enamel, zirconia (IPS e.max ZirCAD MT; Ivoclar AG), and lithium disilicate (IPS e.max CAD; Ivoclar AG) shaped into a spherical stylus. Each specimen was subjected to 50 000 mastication cycles using an oral wear simulator (Oregon Health Sciences University (OHSU) Wear Machine), with a frequency of 1.1 Hz and a maximum 50-N load with vertical load and horizontal movement. The surfaces of the substrate and styli were before and after wear testing using a laboratory scanner (E4 scanner; 3Shape A/S). The surfaces of each specimen before and after wear testing were analyzed using a software program (WearCompare; Leeds Digital Dentistry). The volume difference between the before and after scans were determined for both the substrate and the stylus and analyzed using a 2-way ANOVA. The statistical significance between groups was determined using the Tukey-Kramer HSD test (α=.025). RESULTS: The results of the 2-way ANOVA showed that the antagonist material (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Clinical Assistant Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio. Electronic address: arreazahernandez.1@osu.edu.
- Professor Emeritus, Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio.
- Associate Professor and Director of Student Research, Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio.
- Professor Emeritus and Chair of Institutional Effectiveness Committee, Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio.
- Associate Professor and Director of the Advanced Prosthodontics Program, Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio.
Zitieren
APA
Arreaza, C., Seghi, R. R., Schricker, S. R., Johnston, W. M., & Saponaro, P. C. (2026). Comparison of wear behavior of occlusal device materials manufactured by different processes. The Journal of Prosthetic Dentistry, 135(3), 614.e1-614.e7. https://doi.org/10.1016/j.prosdent.2025.10.040
Vancouver
Arreaza C, Seghi RR, Schricker SR, Johnston WM, Saponaro PC. Comparison of wear behavior of occlusal device materials manufactured by different processes. The Journal of Prosthetic Dentistry. 2026;135(3):614.e1-614.e7. doi:10.1016/j.prosdent.2025.10.040
BibTeX
@article{Arreaza2026,
author = {Arreaza, Catherine and Seghi, Robert R and Schricker, Scott R and Johnston, William M and Saponaro, Paola C},
title = {Comparison of wear behavior of occlusal device materials manufactured by different processes},
journal = {The Journal of Prosthetic Dentistry},
year = {2026},
volume = {135},
number = {3},
pages = {614.e1--614.e7},
doi = {10.1016/j.prosdent.2025.10.040}
}
EUVIMED