EUVIMEDEUVIMED entdecken
Open Access

Feasibility of a UTE Stack‐of‐Spirals Sequence for T 1ρ Mapping of Achilles Tendinopathy

Anmol Monga iD, Hector L de Moura iD, Vaibhavi Rathod iD, Marcelo V W Zibetti iD, Smita Rao iD, Ravinder Regatte iD

NMR in Biomedicine · 2025

DOI: 10.1002/nbm.70149 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, 2025. Verfasst von Anmol Monga und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Achilles Tendon, Tendinopathy, Imaging, Three-Dimensional. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIH HHS, NIAMS NIH HHS, NIBIB NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We analyzed the feasibility of using a UTE stack‐of‐spirals turbo FLASH (STFL) sequence to measure T 1ρ relaxation in the Achilles tendon. Six HS (25–31 years) and five AT patients (32–47 years) participated. The study evaluates the clinical utility of the STFL sequence to generate T 1ρ maps using mono‐exponential (ME) and bi‐exponential (BE) fitting models. In a phantom experiment, ME‐T 1ρ values and SNR estimated from the STFL sequence are compared with those of the Cartesian turbo FLASH (CTFL) sequence. In human subjects, we evaluate differences in estimated ME (ME‐T 1ρ ) and BE parameters (short T 1ρ , long T 1ρ , and short fraction) between AT and HS groups along with repeatability of STFL. The agarose phantom demonstrates biases of 2.89% (3% agarose), −1.88% (5%), and −0.92% (7%) between ME‐T 1ρ values from STFL and CTFL. In the bovine Achilles tendon, STFL shows a large bias of −58.6%, with a lower median ME‐T 1ρ (2.9 ms) than CTFL (4.6 ms). SNR is higher in STFL (77.05–80.72 for 3%–7% agarose; 24.43 for bovine tendon) than CTFL (66.73–58.97 for agarose; 3.21 for bovine tendon). ME and BE parameters were averaged over the entire Achilles tendon, and none showed significant group differences ( p > 0.05; effect size = 0.05–0.22). Subregional analysis showed that in the mid‐Achilles tendon, short and long BE‐T 1ρ components were 26% and 37% lower in AT than HS, though not statistically significant. The LDA‐combined BE parameter showed significant group separation in the midtendon region ( p = 0.016; effect size = 1.53). In HS, the long BE‐T 1ρ component showed subregional variation ( p = 0.006), increasing 58% from calcaneal to midtendon, and then decreasing 23% toward the intramuscular region. ME and BE fitting showed high repeatability with scan‐rescan variations of 2.64% (T 1ρ ), 3.38% (short T 1ρ ), 3.0% (long T 1ρ ), and 0.21% (short fraction). We demonstrated the feasibility of using STFL for T 1ρ quantification in the Achilles tendon.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingAchilles TendonTendinopathyImaging, Three-DimensionalFeasibility StudiesPhantoms, ImagingSignal-To-Noise RatioAnimalsCattleHumansAdultMaleFemaleReproducibility of Results

Stichwörter der Autor:innen

Achilles tendonquantitative mappingrelaxometryrepeatabilitytendinopathyultrashort echo time

Autor:innen und Institutionen

  • Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA.
  • Department of Physical Therapy, New York University, New York, New York, USA.
  • Department of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, Virginia, USA.

ORCID-Profile: Anmol Monga, Hector L de Moura, Vaibhavi Rathod, Marcelo V W Zibetti, Smita Rao, Ravinder Regatte

Förderung

  • NIH HHS
  • NIAMS NIH HHS
  • NIBIB NIH HHS
  • National Institutes of Health

Zitieren

APA

Monga, A., de Moura, H. L., Rathod, V., Zibetti, M. V. W., Rao, S., & Regatte, R. (2025). Feasibility of a UTE Stack‐of‐Spirals Sequence for T 1ρ Mapping of Achilles Tendinopathy. NMR in Biomedicine. https://doi.org/10.1002/nbm.70149

Vancouver

Monga A, de Moura HL, Rathod V, Zibetti MVW, Rao S, Regatte R. Feasibility of a UTE Stack‐of‐Spirals Sequence for T 1ρ Mapping of Achilles Tendinopathy. NMR in Biomedicine. 2025. doi:10.1002/nbm.70149

BibTeX
@article{Monga2025,
  author = {Monga, Anmol and de Moura, Hector L and Rathod, Vaibhavi and Zibetti, Marcelo V W and Rao, Smita and Regatte, Ravinder},
  title = {Feasibility of a UTE Stack‐of‐Spirals Sequence for T 1ρ Mapping of Achilles Tendinopathy},
  journal = {NMR in Biomedicine},
  year = {2025},
  doi = {10.1002/nbm.70149}
}