EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

B1+ Optimization in the Heart at 7 T

Erin McConnell Montoya, Aaron T. Hess, Damian J. Tyler, Ladislav Valkovič

Magnetic Resonance in Medicine · 17.11.2026

DOI: 10.1002/mrm.70670 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 17.11.2026. Verfasst von Erin McConnell Montoya und 3 weiteren Autor:innen. Die Arbeit nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Wellcome Trust, British Heart Foundation, Vedecká Grantová Agentúra MŠVVaŠ SR a SAV.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

At 7 T, the short RF wavelength in tissue (∼11 cm) causes destructive interference within the chest, leading to inhomogeneity and posing a critical challenge for cardiac MRI and MRS. While subject‐specific parallel‐transmit (pTx) optimization can mitigate this, it requires calibration scans and offline computation. To simplify this process, a static “global” shim was calculated and demonstrated to outperform the default transmit configuration without participant‐specific calibration. Methods maps were acquired in 12 healthy volunteers at 7 T using an 8‐channel 1 H torso coil. “Personal” phase‐only shims were calculated per subject by minimizing a cost function of homogeneity and efficiency. The “global” shim was calculated by optimizing performance across the cohort, then validated in six additional volunteers by comparing performance against the native mode.

Results

In the validation cohort, the “global” significantly outperformed the native shim. It increased the Mean Transmit Sensitivity by ∼20% and reduced CoV by in the septum. The fixed global shim performance was within 3% of the computationally expensive personal shim for all metrics.

Conclusion

A fixed, population‐derived, global phase shim provides a practical, calibration‐free approach for improving cardiac performance at 7 T. The present results extend previous universal RF‐shimming work through prospective evaluation in an independent validation cohort and demonstrate that much of the benefit of personal shimming can be retained without participant‐specific optimization. The resulting fixed‐phase configuration could also provide a practical route towards implementation on single‐transmit hardware for cardiac imaging and spectroscopic applications.

Förderung

  • Wellcome Trust
  • British Heart Foundation
  • Vedecká Grantová Agentúra MŠVVaŠ SR a SAV
  • Agentúra na Podporu Výskumu a Vývoja
  • Biotechnology and Biological Sciences Research Council
  • National Institute for Health and Care Research

Zitieren

APA

Montoya, E. M., Hess, A. T., Tyler, D. J., & Valkovič, L. (2026). B1+ Optimization in the Heart at 7 T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70670

Vancouver

Montoya EM, Hess AT, Tyler DJ, Valkovič L. B1+ Optimization in the Heart at 7 T. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70670

BibTeX
@article{Montoya2026,
  author = {Montoya, Erin McConnell and Hess, Aaron T. and Tyler, Damian J. and Valkovič, Ladislav},
  title = {B1+ Optimization in the Heart at 7 T},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70670}
}
Kostenlos starten →