Accelerated 3D multi‐channel B1+ mapping at 7 T for the brain and heart
Magnetic Resonance in Medicine · 2024-11 · 92 (5) · 2007-2020
DOI: 10.1002/mrm.30201 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 27.06.2024. Verfasst von James L Kent und 5 weiteren Autor:innen. Beteiligte Einrichtung: Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK. Hauptthemen laut MEDLINE: Brain, Heart, Magnetic Resonance Imaging, Algorithms. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Vedecká Grantová Agentúra MŠVVaŠ SR a SAV, Wellcome Trust, Royal Society.
Abstract (Originalsprache)
Purpose
To acquire accurate volumetric multi‐channel maps in under 14 s whole‐brain or 23 heartbeats whole‐heart for parallel transmit (pTx) applications at 7 T. Theory and Methods We evaluate the combination of three recently proposed techniques. The acquisition of multi‐channel transmit array maps is accelerated using transmit low rank (TxLR) with absolute mapping (Sandwich) acquired in a time‐interleaved acquisition of modes (B1TIAMO) fashion. Simulations using synthetic body images derived from Sim4Life were used to test the achievable acceleration for small scan matrices of 24 × 24. Next, we evaluated the method by retrospectively undersampling a fully sampled library of nine subjects in the brain. Finally, Cartesian undersampled phantom and in vivo images were acquired in both the brain of three subjects (8Tx/32 receive [Rx]) and the heart of another three subjects (8Tx/8Rx) at 7 T.
Results
Simulation and in vivo results show that volumetric multi‐channel maps can be acquired using acceleration factors of 4 in the body, reducing the acquisition time to within 23 heartbeats, which was previously not possible. In silico heart simulations demonstrated a RMS error to the fully sampled native resolution ground truth of 4.2° when combined in first‐order circularly polarized mode (mean flip angle 66°) at an acceleration factor of 4. The 14 s 3D maps acquired in the brain have a RMS error of 1.9° to the fully sampled (mean flip angle 86°).
Conclusion
The proposed method is demonstrated as a fast pTx calibration technique in the brain and a promising method for pTx calibration in the body.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.
- Spinoza Centre for Neuroimaging, Amsterdam, The Netherlands.
- Computational Cognitive Neuroscience and Neuroimaging, Netherlands Institute for Neuroscience, KNAW, Amsterdam, The Netherlands.
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands.
- Research & Collaborations GB&I, Siemens Healthcare Ltd, Camberley, UK.
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada.
ORCID-Profile: James L Kent, Matthijs H S de Buck, Mark Chiew, Ladislav Valkovič, Aaron T Hess
Förderung
- Vedecká Grantová Agentúra MŠVVaŠ SR a SAV
- Wellcome Trust
- Royal Society
- Engineering and Physical Sciences Research Council
- Agentúra na Podporu Výskumu a Vývoja
- Department of Health
Zitieren
APA
Kent, J. L., de Buck, M. H. S., Dragonu, I., Chiew, M., Valkovič, L., & Hess, A. T. (2024). Accelerated 3D multi‐channel B1+ mapping at 7 T for the brain and heart. Magnetic Resonance in Medicine, 92(5), 2007-2020. https://doi.org/10.1002/mrm.30201
Vancouver
Kent JL, de Buck MHS, Dragonu I, Chiew M, Valkovič L, Hess AT. Accelerated 3D multi‐channel B1+ mapping at 7 T for the brain and heart. Magnetic Resonance in Medicine. 2024;92(5):2007-2020. doi:10.1002/mrm.30201
BibTeX
@article{Kent2024,
author = {Kent, James L and de Buck, Matthijs H S and Dragonu, Iulius and Chiew, Mark and Valkovič, Ladislav and Hess, Aaron T},
title = {Accelerated 3D multi‐channel B1+ mapping at 7 T for the brain and heart},
journal = {Magnetic Resonance in Medicine},
year = {2024},
volume = {92},
number = {5},
pages = {2007--2020},
doi = {10.1002/mrm.30201}
}
EUVIMED